Related Experiment Video
Updated: Jul 11, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Stent Strut Dilation in Branch Pulmonary Artery Stenosis Following Stenting of Arterial Duct in Duct-dependent
Nageswara Rao Koneti1, Shweta Bakhru2, Bhargavi Dhulipudi2
1Consultant Pediatric Cardiologist, Rainbow Children's Heart Institute, Hyderabad, India. drkoneti@yahoo.com.
Abstract:
To assess the feasibility and outcome of stent strut dilation after arterial duct stenting with associated branch pulmonary artery (BPA) stenosis. Stenting of arterial duct in infants with duct-dependent pulmonary circulation is technically challenging. The presence of BPA stenosis is a relative contraindication for stent implantation. Infants with duct-dependent pulmonary circulation and associated BPA stenosis were assessed either by transthoracic echocardiogram alone or additional computerized tomography angiogram when required. Following ductal stenting, the stent struts of the stenosed BPA were crossed with an additional 0.014″ coronary guide wire and dilated using coronary balloons (2.0 or 2.5 mm in diameter). Seventeen (12 male) patients were considered for the procedure. The median age and weight were 27 days (range 2-94) and 2.6 kg (range 2.2-5), respectively. Fourteen patients (82.4%) underwent stent strut dilation after arterial duct stenting. Struts to left pulmonary artery was opened in 9 (64.3%) and right pulmonary artery in 5 (35.7%). The mean systemic oxygen saturation increased from 66.23 ± 8.9% at baseline to 86 ± 2.2% immediately after the stent deployment and final saturations after stent strut dilation were 89.29 ± 4.3%. Angiographic pulmonary flow improved in all cases. Stent strut dilation could not be done in 3 patients due to unfavorable anatomy. One patient had acute stent thrombosis and died in the hospital. Two others died during follow-up, during an acute febrile illness and gastroenteritis. All survivors underwent cardiac surgery and were on regular follow-up. Strut dilation of BPA stenosis is feasible to augment pulmonary blood flow, following arterial duct stenting. This procedure may be useful in selected patients with BPA stenosis to have uniform growth of pulmonary arteries.
More Related Videos
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Stenosis I: Introduction