Use of acoustic cardiography to assess left ventricular electromechanical synchronization during left bundle branch
Xianhao Wu1, Wei Hu1, Lei Song1
1Department of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Background:
Left bundle branch pacing (LBBP) is a physiological pacing that captures the main left bundle or its proximal branch. Electromechanical activation time (EMAT) is an acoustic cardiographic metric that provides a simple method for evaluating left ventricular (LV) synchrony. Prolonged EMAT reflects impaired LV electromechanical coupling.
Objective:
The purpose of this study was to explore whether EMAT can confirm that LBBP produces more satisfactory LV electromechanical synchronization than conventional right ventricular pacing modalities.
Methods:
Patients with standard pacing indications and narrow QRS duration were recruited for this study. Unipolar pacing under 3 different modalities-right ventricular apical pacing (RVAP), right ventricular high septal pacing (RVHSP), and LBBP-were successively performed in each patient. Pacing parameters, echocardiographic characteristics, and acoustic cardiographic parameters at different pacing modalities and during normal rhythm were collected.
Results:
A total of 55 patients were enrolled, and all had successful LBBP. Left ventricular activation time (LVAT) was significantly associated with EMAT, with LVAT vs EMAT correlation coefficient of 0.665 (P <.001). LVAT during LBBP was shorter than that during RVHSP (51.93 ± 2.732 ms vs 85.59 ± 2.240 ms; P <.001). EMAT of LBBP was significantly lower than either RVAP or RVHSP (95.44 ± 1.794 ms vs 143.32 ± 2.376 ms, and 132.22 ± 1.872 ms; both P <.001) but was similar to that of intrinsic rhythm (95.37 ± 2.271 ms; P = .862).
Conclusion:
We found EMAT significantly prolonged in RVHSP and RVAP but not in the LBBP mode. This finding indicates superior electromechanical synchronization in patients having LBBP. EMAT measurement could be an additional method for identifying the ideal pacing position.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrophysiology of Normal Cardiac Rhythm


