Improving the accuracy of blood pressure measuring devices in Australia: a modelled return on investment study
Zachary Desson1, James E Sharman2, Andrew Searles3
1Health Research Economics, Hunter Medical Research Institute, Newcastle, NSW, Australia.
Abstract:
The VALID BP project was initiated to increase the availability of validated blood pressure measuring devices (BPMDs). The goal is to eliminate non validated BPMDs and minimise over- and underdiagnosis of hypertension caused by inaccurate readings. This study was undertaken to assess the potential return on investment in the VALID BP project. The Framework to Assess the Impact of Translational Health Research was applied to the VALID BP project. This paper focuses on the implementation of the cost benefit analysis aspect of this framework to monetise past research investment and model future research costs, implementation costs, and benefits. Analysis was based on reasoned assumptions about potential impacts from availability and use of validated BPMDs (assuming an end goal of 100% validated BPMDs available in Australia by 2028) and improved skills leading to more accurate BP measurement. After 5 years, with 20% attribution of benefits, there is a potential $1.14-$1.30 return for every dollar spent if the proportion of validated BPMDs and staff trained in proper BP measurement technique increased from 20% to 60%. After eight years (2020-2028) and assuming universal validation and training coverage, the returns would be between $2.70 and $3.20 per dollar spent (not including cost of side effects of unnecessary medication or downstream patient impacts from unmanaged hypertension). This modelled economic analysis indicates there will be positive downstream economic benefits if the availability of validated BPMDs is increased. The findings support ongoing efforts toward a universal regulatory framework for BPMDs and can be considered within more detailed future economic analyses.
More Related Videos
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)