Loop Gain as a Predictor of Blood Pressure Response in Patients Treated for Obstructive Sleep Apnea: Secondary
Christopher N Schmickl1, Jeremy E Orr1, Scott A Sands2
1Division of Pulmonary, Critical Care and Sleep Medicine, University of California, San Diego, San Diego, California.
Abstract:
Rationale: Randomized trials have shown inconsistent cardiovascular benefits from obstructive sleep apnea (OSA) therapy. Intermittent hypoxemia can increase both sympathetic nerve activity and loop gain ("ventilatory instability"), which may thus herald cardiovascular treatment benefit. Objectives: To test the hypothesis that loop gain predicts changes in 24-hour mean blood pressure (MBP) in response to OSA therapy and compare its predictive value against that of other novel biomarkers. Methods: The HeartBEAT (Heart Biomarker Evaluation in Apnea Treatment) trial assessed the effect of 12 weeks of continuous positive airway pressure (CPAP) versus oxygen versus control on 24-hour MBP. We measured loop gain and hypoxic burden from sleep tests and identified subjects with a sleepy phenotype using cluster analysis. Associations between biomarkers and 24-h MBP were assessed in the CPAP/oxygen arms using linear regression models adjusting for various covariates. Secondary outcomes and predictors were analyzed similarly. Results: We included 93 and 94 participants in the CPAP and oxygen arms, respectively. Overall, changes in 24-hour MBP were small, but interindividual variability was substantial (mean [standard deviation], -2 [8] and 1 [8] mm Hg in the CPAP and oxygen arms, respectively). Higher loop gain was significantly associated with greater reductions in 24-hour MBP independent of covariates in the CPAP arm (-1.5 to -1.9 mm Hg per 1-standard-deviation increase in loop gain; P ⩽ 0.03) but not in the oxygen arm. Other biomarkers were not associated with improved cardiovascular outcomes. Conclusions: To our knowledge, this is the first study suggesting that loop gain predicts blood pressure response to CPAP therapy. Eventually, loop gain estimates may facilitate patient selection for research and clinical practice. Clinical trial registered with www.clinicaltrials.gov (NCT01086800).
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Measurement of Blood Pressure
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Factors affecting Blood pressure
Physiological Factors: