Related Experiment Video
Updated: Aug 10, 2026

Assessing Cortical Cerebral Microinfarcts on High Resolution MR Images
Published on: November 20, 2015
Influence of scan duration on dynamic contrast -enhanced magnetic resonance imaging pharmacokinetic parameters for
Silvia Minosse1, Eliseo Picchi2, Valentina Ferrazzoli3
1Diagnostic Imaging Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Viale Oxford 81, Rome 00133, Italy.
Objective:
Gadolinium-based contrast agent needs time to leak into the extravascular-extracellular space, leak back into the vascular space, and reach an equilibrium state. For this reason, acquisition times of <10 min may cause inaccurate estimation of pharmacokinetic parameters. Since no studies have been conducted on the influence of long scan times on DCE-MRI parameters in brain tumors, the aim of this study is to investigate the variation of DCE-MRI-derived kinetic parameters as a function of acquisition time, from 5 to 10 min in brain tumors.
Materials And Methods:
Fifty-two patients with histologically confirmed brain tumors were enrolled in this retrospective study, and examination at 3 T, DCE-MRI, with scan duration of 10 min, was used for retrospective generation of 6 sets of quantitative DCE-MRI maps (Ktrans, Ve and Kep) from 5 to 10 min. Features were extracted from the DCE-MRI maps in contrast enhancement (CE) volumes. Kruskal-Wallis with post-hoc correction and coefficient of variation (CoV) were used as statistical test to compare DCE-MRI maps obtained from 6 data sets.
Significance:
p < 0.05.
Results:
No differences in Ktrans features in CE volumes between different scan durations. Ve, Kep features in CE volumes were influenced by different data length. The highest number of significantly different Ve and Kep features in CE volumes were between 5 min and 10 min (p < 0.013), 5 min and 9 min (p < 0.044), 6 min and 10 min (p < 0.040). CoV of Kep was reduced from 5 min to 10 min, going from highly variable (CoV = 0.70) to mildly variable (CoV = 0.42).
Conclusion:
Kep and Ve were time-dependent in brain tumors, so a longer scan time is needed to obtain reliable parameter values. Ktrans was found to be time-independent, as it remains the same in all 6 acquisition times and is the only reliable parameter with short acquisition times.
Related Concept Videos
Magnetic Resonance Imaging
Pharmacokinetic–Pharmacodynamic Relationship: Duration of Dose-Effect Relationship
Pharmacokinetic–Pharmacodynamic Relationship: Influence of Elimination Half-Life on Effect Duration

