Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Thermal expansion and Thermal stress: Problem Solving01:27

Thermal expansion and Thermal stress: Problem Solving

1.2K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
1.2K
Self-Locking Screw01:16

Self-Locking Screw

1.6K
A square-threaded screw jack is a mechanical device widely used for lifting heavy loads or applying considerable force. One of the key features that can make a screw jack more effective and reliable is its self-locking capability.
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
1.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Development of a new operative 3D printed template-cranioplasty-concept for performing craniotomy in the posterior cranial fossa and validation of the system using a 3D printed simulation model: a preclinical feasibility study.

3D printing in medicine·2026
Same author

Salvage surgery following primary treatment in recurrent vestibular schwannoma: surgical outcomes and progression-free survival- a meta-analysis.

Journal of neuro-oncology·2026
Same author

Radiomic hemorrhage roundness predicts outcome beyond the ICH score in deep intracerebral hemorrhage with IVH.

Journal of neurology·2026
Same author

Individualized anticoagulation monitoring in critically ill patients: study protocol for a prospective observational comparison of Anti-Xa, viscoelastic testing, and thrombin generation.

Frontiers in medicine·2026
Same author

BRIDGE: Burr hole vs. craniotomy - radiomic indicators determining the chronification grid in acute subdural hematoma evaluation.

Brain & spine·2026
Same author

Impact of epileptic seizures on functional outcome after subdural haematoma: a systematic review and meta-analysis.

Stroke and vascular neurology·2026

Related Experiment Video

Updated: Jul 11, 2025

Author Spotlight: Rapid Prototyping and Testing of Self-Expanding Nitinol Frames for Transcatheter Implantable Devices
06:53

Author Spotlight: Rapid Prototyping and Testing of Self-Expanding Nitinol Frames for Transcatheter Implantable Devices

Published on: March 7, 2025

375

A New Concept for Cervical Expansion Screws Using Shape Memory Alloy: A Feasibility Study.

Ronny Grunert1,2, Dirk Winkler1, Nikolas Knoop1

  • 1Department of Neurosurgery, University Leipzig, Leipzig, Germany.

Journal of Neurological Surgery. Part A, Central European Neurosurgery
|November 8, 2023
PubMed
Summary

This study explored a new type of cervical screw that uses shape memory alloy to improve stability in weak bone. Traditional screws rely on strong bone density, but this design adapts to low-density bone through temperature changes. The researchers used computer modeling to test different screw and actuator configurations. They found that a 4 mm screw with a 0.8 mm actuator, 7.8 mm slot, and 25-degree angle of attack provided the best balance of strength and efficiency. The shape memory material expands when heated, increasing the screw's grip. Body temperature can activate this expansion, making the design self-regulating. The study suggests that this approach may offer better fixation in osteoporotic bone than traditional methods.

Keywords:
Shape memory alloyCervical screwOrthopedic implantPrimary stabilityBone fixation

Frequently Asked Questions

More Related Videos

Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation
11:11

Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation

Published on: May 2, 2016

11.1K
Fabrication of a Bioactive, PCL-based "Self-fitting" Shape Memory Polymer Scaffold
09:37

Fabrication of a Bioactive, PCL-based "Self-fitting" Shape Memory Polymer Scaffold

Published on: October 23, 2015

12.7K

Related Experiment Videos

Last Updated: Jul 11, 2025

Author Spotlight: Rapid Prototyping and Testing of Self-Expanding Nitinol Frames for Transcatheter Implantable Devices
06:53

Author Spotlight: Rapid Prototyping and Testing of Self-Expanding Nitinol Frames for Transcatheter Implantable Devices

Published on: March 7, 2025

375
Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation
11:11

Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation

Published on: May 2, 2016

11.1K
Fabrication of a Bioactive, PCL-based "Self-fitting" Shape Memory Polymer Scaffold
09:37

Fabrication of a Bioactive, PCL-based "Self-fitting" Shape Memory Polymer Scaffold

Published on: October 23, 2015

12.7K

Area of Science:

  • Orthopedic implant design
  • Biomechanical engineering
  • Smart materials in medical devices

Background:

Orthopedic implants rely on strong anchoring for primary stability, especially in compromised bone conditions like osteoporosis. Traditional methods face limitations in such cases. Prior research has shown that conventional screws may not provide adequate fixation when bone density is low. This gap motivated the exploration of alternative materials and mechanisms. Shape memory alloys have been studied for their temperature-responsive deformation properties. However, their application in orthopedic screws remains underexplored. This study aims to address the need for improved fixation in weak bone environments. The challenge lies in translating material properties into functional implant design. The focus is on developing a novel screw concept that leverages shape memory behavior.

Purpose Of The Study:

This study aimed to evaluate the feasibility of using shape memory alloys in cervical expansion screws. The goal was to enhance primary stability in osteoporotic bone. The researchers sought to identify optimal design parameters for the screw and actuator. They focused on geometric features that influence force development. The study aimed to determine how screw slot length, actuator dimensions, and angle of attack affect performance. The motivation was to create a screw that adapts to bone conditions through temperature changes. The researchers wanted to test whether shape memory properties could improve anchoring. The study also aimed to assess the potential of body temperature as an activation mechanism.

Main Methods:

The researchers used finite element analysis to model the screw and actuator system. They varied parameters like slot length, actuator diameter, and angle of attack. The analysis focused on how these variables affect force development. They simulated different configurations to find the most efficient design. The study considered the mechanical interaction between the screw and shape memory element. The researchers evaluated the impact of each parameter on overall performance. They prioritized configurations that maximize strength while minimizing size. The goal was to identify a balance between component dimensions and functional efficiency.

Main Results:

The optimal screw diameter was found to be 4 mm for maximum strength. An actuator diameter of 0.8 mm was identified as effective. The screw slot length of 7.8 mm contributed to high efficiency. An angle of attack of 25 degrees was shown to enhance force development. The FEA predicted a favorable compromise between component size and performance. The study demonstrated that shape memory elements can generate significant force. The results suggest that body temperature can activate the screw effectively. The configuration achieved high primary stability in simulated conditions.

Conclusions:

The study suggests that shape memory alloys can improve screw fixation in weak bone. The optimal design parameters were identified through FEA modeling. The researchers propose that body temperature can activate the shape memory effect. The findings suggest that the screw configuration enhances primary stability. The study supports the feasibility of using shape memory elements in orthopedic screws. The results indicate that mechanical and thermal properties can be combined effectively. The researchers suggest that this approach may offer advantages over traditional methods. The study concludes that the screw design shows potential for clinical application.

The alloy generates force through temperature changes, enhancing anchoring in weak bone.

The slot allows the actuator to expand, increasing the screw's grip on the bone.

A 25-degree angle optimizes force distribution for maximum stability.

Body temperature triggers the shape memory effect, initiating expansion.

An actuator diameter of 0.8 mm was found to balance strength and efficiency.

The design may offer improved fixation in osteoporotic bone, suggesting potential for clinical application.