Related Experiment Video
Updated: Jul 11, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Cardiac Amyloid Detection by PET/CT Imaging of Iodine (124I) Evuzamitide (124I-p5+14): A Phase 1/2 Study
Jonathan S Wall1, Emily B Martin1, Ronald Lands1
1Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, Tennessee, USA.
Background:
The noninvasive detection of cardiac amyloid, as well as deposits in other vital organs, is critical for early diagnosis and quantitative disease monitoring. Positron emission tomography is an intrinsically quantitative imaging modality suitable for high-resolution amyloid detection.
Objectives:
This study sought to evaluate the safety and efficacy of a novel amyloid-reactive peptide, designated p5+14, labeled with iodine-124 (124I), in patients with diverse types of systemic amyloidosis.
Methods:
In a single-site, open label phase 1/2 study (NCT03678259), the safety, biodistribution, and sensitivity of a single intravenous infusion of 124I-evuzamitide was assessed in patients with systemic amyloidosis (n = 50), asymptomatic transthyretin sequence variant carriers (n = 2), and healthy volunteers (n = 5). Subjects were administered 1.4 ± 0.2 mg of 124I-evuzamitide (71.5 ± 12.4 MBq) and positron emission tomography/x-ray computed tomography images acquired at 5.2 hours (Q25-Q75: 4.9-5.4 hours) postinfusion. Images were assessed visually and semi-quantitatively for positive uptake of radiotracer in the heart and other major organs.
Results:
Uptake of 124I-evuzamitide in the heart and other abdominothoracic organs was consistent with the patient's clinical presentation and the type of amyloidosis. The patient- and cardiac-associated sensitivity for imaging and clinical observations was 93.6% (95% CI: 82.8%-97.8%) and 96.2% (95% CI: 81.8%-99.8%), respectively. Semi-quantitative uptake of the radiotracer correlated significantly with serum N-terminal pro-B-type natriuretic peptide measurements in patients with light chain-associated amyloidosis. Cardiac uptake was not observed in any healthy volunteers. The agent was well tolerated, with 1 drug-related adverse event and no deaths.
Conclusions:
124I-evuzamitide is an amyloid-binding radiotracer capable of detecting cardiac amyloid in patients with high sensitivity.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

