Detection of Superheated Steam during Sterilization Using Biological Indicators
Abstract:
Saturated steam (SS) is used for sterilizing many medical devices. Exposure to SS for appropriate temperature/time combinations creates a microbicidal environment that renders product sterile. Superheated steam (SHS) has been heated beyond its saturation point and is less microbicidal, compromising process efficacy. Sterilization monitoring systems should detect SHS. One method is to use biological indicators (BIs; e.g., rapid-readout self-contained BIs [RRSCBIs]). The purpose of this study was to determine if RRSCBIs can detect SHS. Pressurizing the boiler to 4,700 mB, manifold to 4,000 mB, and chamber jacket to 3,600 mB and heating the viewing window to 150°C in a 10-L BI evaluation resistometer vessel allowed approximately 12°C and 4.5°C of superheat in a nominal 121.75 ± 0.25°C and 132.5 ± 0.25°C cycle, respectively, to be reproducibly achieved. Replicate tests using multiple RRSCBIs from different batches were exposed vertically (cap up), inverted (cap down), and horizontally to SS and SHS. RRSCBI viability was determined using a fluorescent readout method. RRSCBIs exposed to SS at 121.75 ± 0.25°C for 7 or 14 minutes were negative. A total of 135 type A RRSCBIs were exposed to SHS (12°C) at 121.75 ± 0.25°C for 14 minutes. Zero of 45 RRSCBIs mounted vertically showed a positive fluorescent result, 26 of 45 mounted inverted were positive, and 45 of 45 mounted horizontally were positive. A total of 135 type B RRSCBIs were exposed to SHS (12°C) at 121.75 ± 0.25°C for 7 minutes. Twenty-four of 45 mounted vertically were positive, 41 of 45 mounted inverted were positive, and 45 of 45 mounted horizontally were positive. RRSCBIs detected SHS, but this was orientation dependent. Further work is required to establish the application of these findings in healthcare facility settings.
More Related Videos
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Key Techniques in Microbiology