Related Experiment Video
Updated: Jul 11, 2025

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Estimation of target occupancy in repeated dosing design studies using positron emission tomography: Biases due to
Eugenii A Rabiner1, Roger N Gunn1,2
1Invicro, London, UK.
Abstract:
Positron emission tomography (PET) has become indispensable in the quantification of target engagement by brain targeting medications. The relationship between the drug plasma concentration (or drug dose administered) and target occupancy determined during a PET occupancy study has provided valuable information for the assessment of novel pharmaceuticals in the early phases of drug development. Such information is also critical for the understanding of the mechanisms of action and side-effect profile of approved medication commonly used in the clinic. Occupancy studies conducted following repeated drug dosing (RD) can produce systematic differences from those conducted following single drug dose (SD), differences that have not been adequately explored. We have hypothesised that when differences are observed between RD and SD studies, they are related to changes in target density induced by repeated drug accumulation. We have developed a modified occupancy model to account for potential changes in target density and tested it on a sample dataset. We found that target upregulation can parsimoniously explain the differences in drug affinity estimated in SD and RD studies. Our findings have implications for the interpretation of RD occupancy data in the literature and the relationship between specific target occupancy levels and drug efficacy and tolerability.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:07Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Quantitative Aspects of Drug-Receptor Interaction
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET