Purpose:
To investigate the correlation between different ultrasound attenuation-based techniques and to compare their diagnostic performances using proton magnetic resonance spectroscopy (1H-MRS) as a reference standard.
Methods:
Participants who had clinical suspicion of nonalcoholic fatty liver disease (NAFLD) were prospectively recruited. Each subject had ultrasound with attenuation imaging (ATI) or quantitative ultrasound including tissue attenuation imaging (TAI) and tissue scatter-distribution imaging (TSI), and controlled-attenuation parameter (CAP) and 1H-MRS if available. The technical success rates, intra-observer repeatabilities of attenuation and backscattering coefficient were evaluated. ATI, TAI and CAP were three attenuation-based techniques. Spearman coefficient was used to test correlations among them and 1H-MRS. In addition, the diagnostic performances of these parameters for detecting ≥ 5% or 10% hepatic steatosis were evaluated.
Results:
130 participants had ultrasound scanning. Among them, 67 had CAP and 48 had 1H-MRS. The technical success rates were all 100%. The intra-observer repeatabilities of them were also excellent (ICCs > 0.90) and AC-ATI correlated well with AC-TAI (r = 0.752). AC-ATI, AC-TAI showed moderate correlation with CAP, (rATI = 0.623, 95% CI 0.446-0.752, P < 0.001; rTAI = 0.573, 95% CI 0.377-0.720, P < 0.001). For correlation with 1H-MRS, ATI and TAI performed better than CAP(rATI = 0.587; rTAI = 0.712; r CAP = 0.485). The AUCs of ATI, TAI, TSI and CAP for detecting ≥ 5% hepatic steatosis were 0.883, 0.862, 0.870 and 0.868, respectively. The AUC improved to 0.907 when TAI and TSI were combined (P < 0.05). When detecting ≥ 10% hepatic steatosis, the AUCs were 0.855, 0.702, 0.822 and 0.838, respectively.
Conclusion:
Different ultrasound attenuation-based techniques were well correlated and exhibited good diagnostic performances in quantitative diagnosis of hepatic steatosis, however, the threshold values were different. Combinations of multiple parameters may improve the diagnostic performance in detecting hepatic steatosis.
Trial Registration:
The study has been registered online ( https://www.chictr.org.cn ; unique identifier: ChiCTR2300069459).
More Related Videos
05:37Author Spotlight: A Non-Invasive Tool to Assess and Differentiate Fat Patterns in Liver Using 3D Dixon MRI
Published on: October 20, 2023
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...