Tests and deflection calculation method for circular concrete-filled steel tubular columns under very low-elevation

Jiayu Liang1, Yanhui Liu2, Yichao Zhao3

  • 1School of Civil Engineering Southwest, Jiaotong University, Chengdu, 610031, People's Republic of China.

Scientific Reports
|November 13, 2023
PubMed

Related Concept Videos

Design of Columns under a Centric Load01:17

Design of Columns under a Centric Load

The design of columns under centric load is a fundamental aspect of structural engineering and is critical for ensuring the stability and integrity of structures. Euler's and Secant's formulas are central to understanding and calculating the critical load and deformation behaviors of columns, providing a basis for safe and effective structural design.
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
124
Eccentric Loading01:16

Eccentric Loading

Eccentric loading is a crucial concept in the study of structural engineering and mechanics, particularly when analyzing the stability and stress distribution in columns. Unlike centric loading, where the force is applied along the centroidal axis, causing uniform compression, eccentric loading occurs when a force is applied off-center. This off-center application introduces not only direct compressive stress but also bending stress, significantly influencing the column's behavior under...
393
Euler's Formula for Pin-Ended Columns01:21

Euler's Formula for Pin-Ended Columns

In structural engineering, the stability of columns under compressive axial loads is a critical consideration, described as buckling. A typical example involves a column PQ, which is pin-connected at both ends and subjected to a centric axial load F applied at one end, with a reaction force of F' = -F at the other end. Here, it is crucial to understand that when an applied load exceeds the critical load, buckling occurs as the system becomes unstable.
To calculate the critical load,...
324
Euler's Formula to Columns with Other End Conditions01:15

Euler's Formula to Columns with Other End Conditions

Euler's formula is very important in the field of structural engineering, providing a foundation for understanding the critical loading conditions of pin-ended columns. This formula links the modulus of elasticity, the moment of inertia of the cross-section, and the column's length, offering a precise calculation of the critical load at which a column is prone to buckling.
532
Design of Columns under an Eccentric Load01:21

Design of Columns under an Eccentric Load

Designing columns to withstand eccentric loads is a critical aspect of structural engineering, ensuring structures can support off-center loads without failure. This design process must account for the additional normal stresses introduced by eccentric loading, which can significantly influence a column's stress distribution and overall stability. An eccentric load applied to a column induces normal stresses that can be conceptualized as a combination of stresses due to an equivalent...
553
Deflection of a Beam01:19

Deflection of a Beam

Accurately determining beam deflection and slope under various loading conditions in structural engineering is crucial for ensuring safety and structural integrity. Singularity functions offer a streamlined approach to analyzing beams, especially when multiple loading functions complicate the bending moment equation.
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
268