Related Experiment Video
Updated: Jul 11, 2025

Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
Published on: February 9, 2021
Albuminuria Is Affected by Urinary Tract Infection: A Comparison between Biochemical Quantitative Method and
Yi-Ju Chou1, Chun-Chun Yang2, Shang-Jen Chang3
1Division of Urology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, New Taipei 23142, Taiwan.
Abstract:
The automated urine reagent strip test is a cost-effective tool for detecting albuminuria in patients. However, prior research has not investigated how urinary tract infections (UTIs) affect the test's accuracy. Therefore, this study aims to assess the impact of UTIs on albuminuria diagnosis using both the biochemical quantitative method and the test strip method of the Fully Automatic Urine Chemistry Analyzer, UC-3500 (Sysmex, Kobe, Japan). From March to December 2019, we prospectively collected midstream urine from adult female UTI patients before and after one week of cephalexin treatment. The urine samples were subjected to culture, routine urinalysis, and albuminuria diagnosis using the biochemical quantitative method and UC-3500. Albuminuria was defined as a urine albumin to creatinine ratio (UACR) ≥ 30 mg/g in the biochemical quantitative method. The results were compared between the two methods. Among fifty-four female patients (average age: 50.5 ± 4.4 years) with UTIs, 24 (44.44%) had transient albuminuria. The quantitative UACR significantly decreased after one week of antibiotic treatment (median: 53 mg/g to 9 mg/g; median difference: -0.54, p < 0.0001). UC-3500 exhibited a higher false positive rate for diagnosing albuminuria during UTIs (42%) compared to after treatment (19%). Its agreement with the biochemical quantitative method was moderate during UTI (κ = 0.49, 95% confidence interval [CI]: 0.24-0.73) and good after treatment (κ = 0.65, 95% CI: 0.45-0.86). UC-3500's accuracy in diagnosing albuminuria is influenced by UTIs, leading to either transient albuminuria or a false positive reaction of the test strip. UTI should be excluded or treated before its application in albuminuria screening.
Related Concept Videos
Urine Studies I: Urinalysis
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Urinary Tract Calculi III: Medical Management
Urine Studies II: Urine Culture and Sensitivity Test
Serum Studies: Renal Function Tests
Acute Kidney Injury IV: Diagnostic Studies and Prevention

