Jordana Phillips1, Tejas S Mehta1, Leah H Portnow1
1From the Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave, TCC 4th Floor, Boston, MA 02215 (J.P.); Department of Radiology, UMass Memorial Medical Center, Worcester, Mass (T.S.M.); Department of Radiology, Brigham and Women's Hospital, Boston, Mass (L.H.P.); Department of Radiology, Boston University Medical Center, Boston, Mass (J.P., M.D.C.F.); Takeda Pharmaceuticals, Cambridge, Mass (Z.Z.); and Department of Radiology, Penn Medicine, Philadelphia, Pa (E.D.P.).
Abstract:
Background Despite growing interest in using contrast-enhanced mammography (CEM) for breast cancer screening as an alternative to breast MRI, limited literature is available. Purpose To determine whether CEM is noninferior to breast MRI or abbreviated breast MRI (AB MRI) and superior to two-dimensional mammography in an asymptomatic population simulating those who would present for screening and then undergo diagnostic work-up. Materials and Methods This enriched reader study used CEM and MRI data prospectively collected from asymptomatic individuals at a single institution from December 2014 to March 2020. Case sets were obtained at screening, as part of work-up for a screening-detected finding, or before biopsy of a screening-detected abnormality. All images were anonymized and randomized, and all 12 radiologists interpreted them. For CEM interpretation, readers were first shown low-energy images as a surrogate for digital mammography and asked to give a forced Breast Imaging Reporting and Data System score for up to three abnormalities. The highest score was used as the case score. Readers then reviewed the full CEM examination and scored it similarly. After a minimum 1-month washout, the readers similarly interpreted AB MRI and full MRI examinations. Receiver operating characteristic analysis, powered to test CEM noninferiority to full MRI, was performed. Results The study included 132 case sets (14 negative, 74 benign, and 44 malignant; all female participants; mean age, 54 years ± 12 [SD]). The mean areas under the receiver operating characteristic curve (AUCs) for digital mammography, CEM, AB MRI, and full MRI were 0.79, 0.91, 0.89, and 0.91, respectively. CEM was superior to digital mammography (P < .001). No evidence of a difference in AUC was found between CEM and AB MRI and MRI. Conclusion In an asymptomatic study sample, CEM was noninferior to full MRI and AB MRI and was superior to digital mammography. Clinical trial registration no. NCT03482557 and NCT02275871 © RSNA, 2023 Supplemental material is available for this article.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging