Related Experiment Video
Updated: Jul 11, 2025

Quantitative Assessment of Cortical Auditory-tactile Processing in Children with Disabilities
Published on: January 29, 2014
An Absorbance Peak Template for Clinical Assessment of Sound Conduction in Newborn Ears
Hammam A AlMakadma1, Beth F Reed2, Chris A Sanford3
1Department of Otolaryngology-HNS and Communicative Disorders, School of Medicine, University of Louisville, Louisville, KY.
Purpose:
Power absorbance measures recorded over a wide range of frequencies allow for clinical inferences about the outer/middle ears' acoustic mechanics. A frequency-dependent feature in the newborn wideband absorbance response, the prominent mid-frequency absorbance peak, has been linked to middle-ear resonance. However, current normative methods were not designed to assess subtle changes in such features. This work aims to develop and validate an absorbance peak template (APT) for assessment of absorbance peaks in newborns. Additional objectives are to compare test performance of absorbance peaks and APTs to existing normative methods, to demonstrate APT-based methods for categorization of abnormal absorbance peaks, and to describe absorbance peak test-retest variability.
Method:
Peak absorbance and peak frequency were analyzed in a training data set (490 measurements in 84 newborn ears who passed transient evoked otoacoustic emissions [TEOAEs] screenings), and an APT was developed by computing normal limits on these two absorbance peak variables. Split-set analysis evaluated the reproducibility of APT, and test-retest analysis was performed. Test performance analysis, conveyed by area under the receiver operating characteristic curve (AROC) and 95% confidence intervals (CIs), compared absorbance peak variables to absorbance area indices (AAIs) in a validation data set (359 ears that passed distortion-product OAE [DPOAE] screening and 64 ears that failed). APT-based assessment paradigms for normal and abnormal ears were compared to the common absorbance normative range paradigm.
Results:
Split-set analysis demonstrated a good reproducibility of APT, and test-retest of absorbance peak variables showed that they were stable measures for clinical assessment. Test performance of peak absorbance (AROC = 0.83; 95% CI [0.77, 0.88]) was comparable to the top-performing AAI variables (AROC = 0.85; 95% CI [0.80, 0.90]). APT-based assessment categorized measurements based on their peak absorbance and peak frequency and enhanced the detection of subtle frequency changes that were missed by the normative range method.
Conclusion:
Analysis of absorbance peaks guided by APT has the potential to simplify and improve assessments of sound conduction pathways in newborn ears and can be used together with or in-place of current methods for analysis of wideband absorbance data.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
The Cochlea
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Anatomy of the Ear
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same...