Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

1.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
1.3K
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

1.6K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
1.6K
Instrument Calibration01:12

Instrument Calibration

197
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
197

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Regulatory measures for mitigating physical and mental health impacts in aerospace environment: A systematic review.

Life sciences in space research·2025
Same author

Dataset of binocularly coded steady-state visual evoked potentials recorded with an augmented reality headset.

Scientific data·2025
Same author

Adaptive Neurofeedback Training Using a Virtual Reality Game Enhances Motor Imagery Performance in Brain-Computer Interfaces.

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2025
Same author

Corrigendum to "Sendai virus-based immunoadjuvant in hydrogel vaccine intensity-modulated dendritic cells activation for suppressing tumorigenesis" [Bioact. Mater. 6 (2021) 3879-3891].

Bioactive materials·2025
Same author

Enhanced theta oscillations in the left temporoparietal region associated with refractory positive symptoms in schizophrenia.

Schizophrenia (Heidelberg, Germany)·2025
Same author

Cortical changes induced by increased cognitive task difficulty during dual task balancing correlate with postural instability in elders and patients with Parkinson's disease.

Journal of neural engineering·2025

Related Experiment Video

Updated: Jul 11, 2025

A Method for Tracking the Time Evolution of Steady-State Evoked Potentials
12:03

A Method for Tracking the Time Evolution of Steady-State Evoked Potentials

Published on: May 25, 2019

8.5K

Enhancing SSVEP Identification With Less Individual Calibration Data Using Periodically Repeated Component Analysis.

Yufeng Ke, Shuang Liu, Dong Ming

    IEEE Transactions on Bio-Medical Engineering
    |November 16, 2023
    PubMed
    Summary
    This summary is machine-generated.

    Periodically Repeated Component Analysis (PRCA) improves steady-state visually evoked potentials (SSVEP) identification, especially with limited calibration data. This method enhances accuracy and information transfer rates for brain-computer interfaces (BCIs).

    More Related Videos

    A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
    08:23

    A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy

    Published on: November 13, 2016

    11.2K
    SSVEP-based Experimental Procedure for Brain-Robot Interaction with Humanoid Robots
    11:01

    SSVEP-based Experimental Procedure for Brain-Robot Interaction with Humanoid Robots

    Published on: November 24, 2015

    13.2K

    Related Experiment Videos

    Last Updated: Jul 11, 2025

    A Method for Tracking the Time Evolution of Steady-State Evoked Potentials
    12:03

    A Method for Tracking the Time Evolution of Steady-State Evoked Potentials

    Published on: May 25, 2019

    8.5K
    A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
    08:23

    A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy

    Published on: November 13, 2016

    11.2K
    SSVEP-based Experimental Procedure for Brain-Robot Interaction with Humanoid Robots
    11:01

    SSVEP-based Experimental Procedure for Brain-Robot Interaction with Humanoid Robots

    Published on: November 24, 2015

    13.2K

    Area of Science:

    • Neuroscience
    • Biomedical Engineering
    • Signal Processing

    Background:

    • Steady-state visually evoked potentials (SSVEP) identification methods often struggle with small calibration datasets.
    • Existing methods like task-related component analysis (TRCA) rely on inter-trial components, which can be limited with sparse data.

    Purpose of the Study:

    • To introduce a novel method, Periodically Repeated Component Analysis (PRCA), for robust SSVEP identification.
    • To enhance SSVEP identification accuracy and efficiency, particularly when calibration data is scarce.

    Main Methods:

    • PRCA constructs spatial filters to maximize reproducibility across periods and creates synthetic SSVEP templates from periodically repeated components (PRCs).
    • PRCs were integrated into improved TRCA variants.
    • Performance was evaluated on 16-target and 40-target datasets, and in an online experiment.

    Main Results:

    • PRCA-based methods achieved over 95% and 90% accuracy with only 1-second data and a single calibration trial per frequency.
    • High information transfer rates (ITR) were recorded: up to 198.8±57.3 bits/min and 191.2±48.1 bits/min.
    • Online experiments yielded 94.00 ± 7.35% accuracy and 139.73±21.04 bits/min ITR with 0.5-second calibration data.

    Conclusions:

    • PRCA-based methods demonstrate significant performance improvements with reduced calibration data.
    • These methods are effective and robust for SSVEP identification, showing potential for practical SSVEP-BCI applications.