Does trapezium remodeling correlate with cup shape?
Related Experiment Video
Updated: Jul 11, 2025

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
Published on: May 23, 2025
Bram Van Hove1, Pieter Caekebeke1, Joris Duerinckx2
1Department of Orthopaedic Surgery and Traumatology, Ziekenhuis Oost-Limburg, Schiepse Bos 6, 3600 Genk, Belgium.
Abstract:
We investigated whether trapezium bone reaction was different following implantation of a trapeziometacarpal total joint replacement with a hemispheric or a conical cup. Fifty-three Keri Medical Touch implants with hemispheric cup and 53 with conical cup were prospectively followed up radiographically. We compared radiographs taken immediately and one year after surgery for cup subsidence, tilt, heterotopic ossification and loosening. Cup subsidence of at least 1 mm was detected in 4% of cases for both cup types. Additive bone reaction around the cup of more than 1 mm was present in 62% of conical cups and 47% of hemispheric cups. These were minor and there were no large ossifications with risk of impingement. Minor radiolucency was seen superficially at the implant-bone interface of 13% of the hemispheric cups and 9% of the conical cups. None of these bone reactions differed significantly according to cup design.