Related Experiment Video
Updated: Jul 11, 2025

07:46
Setting Limits on Supersymmetry Using Simplified Models
Published on: November 15, 2013
8.6K
Observation of Single-Top-Quark Production in Association with a Photon Using the ATLAS Detector
G Aad1, B Abbott2, D C Abbott3
1CPPM, Aix-Marseille Université, CNRS/IN2P3, Marseille, France.
Physical Review Letters
|November 17, 2023
Summary
Researchers observed single top quarks produced with a photon, directly probing the top quark
Area of Science:
- High Energy Physics
- Particle Physics
- Quantum Chromodynamics
Background:
- The Standard Model of particle physics describes fundamental particles and forces.
- Top quarks are the heaviest known elementary particles.
- Electroweak interactions are fundamental forces described by the Standard Model.
Purpose of the Study:
- To report the observation of single top quarks produced concurrently with a photon.
- To directly probe the electroweak coupling of the top quark.
- To measure the fiducial cross section of this process.
Main Methods:
- Utilized 139 fb⁻¹ of 13 TeV proton-proton collision data.
- Data collected using the ATLAS detector at the Large Hadron Collider.
- Analysis required a photon with transverse momentum > 20 GeV within detector acceptance.
Main Results:
- Measured a fiducial cross section of 688 ± 23 (stat) -71+75 (syst) fb.
- This measurement probes the electroweak coupling of the top quark.
- The measured cross section is compared to the Standard Model prediction.
Conclusions:
- The observation provides direct insight into the top quark's electroweak interactions.
- The measured cross section deviates from the Standard Model prediction.
- This finding contributes to precision measurements in high-energy physics.
Related Concept Videos
Mass Analyzers: Common Types
617
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
617
Tandem Mass Spectrometry
1.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.0K
Atomic Emission Spectroscopy: Overview
2.3K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.3K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
231
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
231

