Are dynamic measurements of central venous pressure in Fontan circulation during exercise or volume loading superior
Alyssia Venna1, Shriprasad Deshpande2, Tacy Downing2
1Division of Cardiac Surgery, Children's National Hospital, Washington, DC, USA.
Background:
The main objective measure to assess the health of the Fontan circulation is the pressure measurement of the superior vena cava or pulmonary arteries. We reviewed the literature for benefits of measuring resting pressure in the Fontan circuit and explored whether dynamic measurement by volume loading or exercise has the potential to refine this diagnostic tool.
Methods:
PubMed was searched for articles showing a relationship between resting post-operative central venous pressure or pulmonary artery pressure and Fontan failure. Relationships between post-operative central venous pressure or pulmonary artery pressure and volume loading changes, such as during exercise or volume loading during cardiac catheterization, were also queried.
Results:
A total of 44 articles mentioned relationships between resting central venous pressure or pulmonary artery pressure and Fontan failure. Only 26 included an analysis between the variables and only seven of those articles found pressure to be predictive of Fontan failure. Ten articles examined the relationship between exercise or volume loading and outcomes and demonstrated a large individual variation of pressures under these dynamic conditions.
Conclusions:
Based on current literature, there is not a lot of strong evidence to show that elevated resting central venous pressure or pulmonary artery pressure is predictive of Fontan failure. Some individuals experience dramatic increases in central venous pressure or pulmonary artery pressure under increased loading conditions with exercise or bolus fluid infusion, while others experience increases closer to that of a healthy control population. Further studies are needed to examine whether more dynamic and continuous monitoring of systemic venous pressures might better predict outcomes in patients with Fontan circulation.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
12:37Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)