Related Experiment Video
Updated: Jul 10, 2025

Bovine Mammary Gland Biopsy Techniques
Published on: December 23, 2018
Seasonal assessment of mastitis using thermogram analysis in Sahiwal cows
S L Gayathri1, M Bhakat1, T K Mohanty1
1Livestock Production Management Division, ICAR- National Dairy Research Institute, Karnal, Haryana 132001, India.
Abstract:
"India is the world's leading producer of milk" and demands a non-invasive diagnostic tool like infrared thermography (IRT) to identify the costliest production disease, mastitis. It can form the basis of precision dairy farming. Therefore, the present study focuses on thermal imaging of the udder and teat quarters of Sahiwal cows during different seasons to identify subclinical (SCM) and clinical mastitis (CM) cases using the Darvi DTL007 camera. A total of 24-69 lactating Sahiwal cows were screened out using IRT regularly throughout the year. The intramammary infection status was further assessed using the CMT. The receiver operating characteristic analysis was carried out to develop the current study's cut-off for various thermographic parameters. The incidence for SCM and CM ranged from 26.47 to 38.75% and 17.83-22.79%, respectively during different seasons in Sahiwal udder quarters. The thermogram analysis revealed a significant difference (p < 0.01) in the mean values of the udder and teat surface temperature of Sahiwal cows between healthy, SCM, and CM during different seasons. The mean values of udder skin surface temperature (USST) during different seasons ranged between 29.07 and 36.91 °C, 31.51 to 37.88 °C and 32.42 to 38.79 °C among healthy, SCM, and CM-affected quarters, and correspondingly, the mean values of teat skin surface temperature (TSST) were 28.28 to 36.77 °C, 30.68 to 37.88 °C and 31.70 to 38.73 °C, respectively. Further results revealed an increase (p < 0.01) in the mean values of USST during winter, summer, rainy, and autumn as 2.44, 3.35; 0.97, 1.88; 1.06, 1.83; 1.29, 2.39 °C and TSST as 2.4, 3.42; 1.11, 1.96; 1.21, 2.19, 1.3, 2.4 °C of SCM, CM-affected quarters to healthy quarters, respectively, in Sahiwal cows. Thermograms showed a strong positive correlation with the CMT scores of SCM, CM cases, and healthy samples. Henceforth, irrespective of the seasons studied in the present work, IRT is an efficient, supportive tool for the early identification of subclinical mastitis.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...

