Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

After Skin Wounding, Noncoding dsRNA Coordinates Prostaglandins and Wnts to Promote Regeneration.

The Journal of investigative dermatology·2017
Same author

Metabolic profiling and novel plasma biomarkers for predicting survival in epithelial ovarian cancer.

Oncotarget·2017
Same author

Identification of a six-lncRNA signature associated with recurrence of ovarian cancer.

Scientific reports·2017
Same author

Ropivacaine versus levobupivacaine in peripheral nerve block: A PRISMA-compliant meta-analysis of randomized controlled trials.

Medicine·2017
Same author

Fabrication of fluorescent composite hydrogel using in situ synthesis of upconversion nanoparticles.

Nanotechnology·2017
Same author

Ammonium assimilation: An important accessory during aerobic denitrification of Pseudomonas stutzeri T13.

Bioresource technology·2017
Same journal

Tailoring oxygen vacancy of WO<sub>3</sub> nanoparticles for high-performance gas sensing: room-temperature NO<sub>2</sub> and low-temperature triethylamine detection.

Talanta·2026
Same journal

Mixed potential acetone sensor based on LaBaCo<sub>2-x</sub>Fe<sub>x</sub>O<sub>5±δ</sub> (x=0, 0.05 and 0.2) sensing electrode and yttria-stabilized zirconia for non-invasive diagnosis of diabetes.

Talanta·2026
Same journal

A nanowire-based fluorescent sensor for detecting hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) dyshomeostasis in cell body and synapse of Alzheimer's disease (AD) cell model.

Talanta·2026
Same journal

Ultra-sensitive determination of cyclopiazonic acid in complex food samples via competitive time-resolved luminescence immunoassays coupled to green microextraction.

Talanta·2026
Same journal

Integrated analytical characterization and multiscale modeling of supramolecular interactions in lumefantrine-curcumin coamorphous systems with enhanced biopharmaceutical and anticancer performance.

Talanta·2026
Same journal

Pixel-wise assessment of industrial compost transformation by NIR hyperspectral imaging and chemometrics: an early-warning tool for process monitoring.

Talanta·2026
See all related articles

Related Experiment Video

Updated: Jul 10, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
09:23

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum

Published on: December 13, 2017

6.3K

Customizable miniaturized SPR instrument.

Xinpu Zhang1, Zeliu Li1, Wen Yan2

  • 1School of Physics, Dalian University of Technology, Dalian, 116024, China.

Talanta
|November 24, 2023
PubMed
Summary
This summary is machine-generated.

A new, compact prism-based surface Plasmon resonance (SPR) system offers high sensitivity and stability. This miniaturized SPR biosensor design enhances flexibility and performance for diverse applications.

Keywords:
CustomizableFPGA-based multifunctional data processingSurface plasmon resonanceSurface plasmon resonance instrument

More Related Videos

A Label-free Technique for the Spatio-temporal Imaging of Single Cell Secretions
09:09

A Label-free Technique for the Spatio-temporal Imaging of Single Cell Secretions

Published on: November 23, 2015

8.6K
Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

1.5K

Related Experiment Videos

Last Updated: Jul 10, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
09:23

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum

Published on: December 13, 2017

6.3K
A Label-free Technique for the Spatio-temporal Imaging of Single Cell Secretions
09:09

A Label-free Technique for the Spatio-temporal Imaging of Single Cell Secretions

Published on: November 23, 2015

8.6K
Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

1.5K

Area of Science:

  • Optoelectronics
  • Biosensing Technology

Background:

  • Prism-based surface Plasmon resonance (SPR) systems are mature, sensitive, and stable, making them suitable for commercial applications.
  • Traditional prism-based SPR systems are often bulky and complex, limiting their widespread adoption and flexibility.

Purpose of the Study:

  • To develop an optimized and compact prism-based SPR system by improving optical design.
  • To create a miniaturized SPR system with customizable performance for various user needs and application scenarios.

Main Methods:

  • Optical system optimization and integrated design were employed to achieve miniaturization.
  • Portable data acquisition and processing technology, specifically FPGA-based multifunctional data processing, was integrated.

Main Results:

  • A customizable, miniaturized prism-based SPR system was successfully developed.
  • The system demonstrates flexibility in configuration and performance customization.
  • The design facilitates differentiated performance optimization for specific applications.

Conclusions:

  • The developed miniaturized prism-based SPR system overcomes the bulkiness of traditional designs.
  • This optimized SPR biosensor offers enhanced flexibility and customizable performance.
  • The system is well-suited for diverse applications requiring tailored sensing solutions.