Bone Mineral Density Derived from Cardiac CT Scans: Using Contrast Enhanced Scans for Opportunistic Screening
Andia Cheneymann1, Josephine Therkildsen2, Simon Winther1
1Department of Cardiology, Gødstrup Hospital, Herning, Denmark.
Purpose:
Osteoporosis is under-diagnosed and often co-exists with other diseases. Very low bone mineral density (BMD) indicates risk of osteoporosis and opportunistic screening for low BMD in CT-scans has been suggested. In a non-contrast enhanced thoracic CT scan, the scan-field-of-view includes vertebrae enabling BMD estimation. However, many CT scans are obtained by administration of contrast material. If the impact of contrast enhancement on BMD measurements could be quantified, considerably more patients are eligible for screening.
Methods:
This study investigated the impact of intravenous contrast on thoracic BMD measurements in cardiac CT scans pre- and post-contrast, including different contrast trigger levels of 130 and 180 Hounsfield units (HU). BMD was measured using quantitative CT with asynchronous calibration.
Results:
In 195 participants undergoing cardiac CT (mean age 57±9 years, 37 % females) contrast increased mean thoracic BMD from 116±33 mg/cm3 (non-enhanced CT) to 130±38 mg/cm3 (contrast-enhanced CT) (p<0.001). Using clinical cut-off values for very low (<80 mg/cm3) and low BMD (<120 mg/cm3) showed that 24 % (47/195 participants) were misclassified when BMD was measured on contrast-enhanced CT-scans. Of the misclassified patients, 6 % (12/195 participants) were categorized as having low BMD despite having very low BMD on the non-enhanced images. Contrast-CT using a higher contrast trigger level showed a significant increase in BMD compared to the lower trigger level (119±32 vs. 135±40 mg/cm3, p<0.01).
Conclusion:
For patients undergoing cardiac CT, using contrast-enhanced images to assess BMD entails substantial overestimation. Contrast protocol trigger levels also affect BMD measurements. Adjusting for these factors is needed before contrast-enhanced images can be used clinically.
Mini Abstract:
Osteoporosis is under-diagnosed. Contrast-enhanced CT made to examine other diseases might be utilized simultaneously for bone mineral density (BMD) screening. These scans, however, likely entails overestimation of BMD due to the effect of contrast. Adjusting for this effect is needed before contrast-enhanced images can be implemented clinically for BMD screening.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...