Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
Published on: November 10, 2014
Droplet manipulation on an adjustable closed-open digital microfluidic system utilizing asymmetric EWOD
Jingsong Xu1, Xingcheng Wang1, Qingyuan Huang1
1School of Information Science and Engineering, Lanzhou University, No. 222 Tianshui South Road, Lanzhou 730000, China. xdhe@lzu.edu.cn.
Abstract:
The closed-open digital microfluidic (DMF) system offers a versatile and powerful platform for various applications by combining the advantages of both closed and open structures. The current closed-open DMF system faces challenges in scaling up due to electrode structural differences between closed and open regions. Here we developed an adjustable closed-open DMF platform by utilizing the modified slippery liquid-infused porous surfaces (SLIPS) with asymmetric electrowetting on dielectric (AEWOD) as a hydrophobic dielectric layer. The consistent electrode structures of the bottom printed circuit board (PCB) electrode array on both the closed and open regions, and the utilization of a transparent acrylic with floating potential as the top plate allow a low-cost and easily scalable closed-open DMF system to be achieved. The impacts of applied voltage, parallel plate spacing, electrode switching interval, and electrode driving strategies on various droplet manipulations were investigated. The results show that the optimal plate spacings range from 340-510 μm within the closed region. Meanwhile, we also studied the influence of the thickness, geometry, and position of the top plate on the droplet movement at the closed-open boundary. Through force analysis and experimentation, it is found that a thin top plate and a bevel of ∼4° can effectively facilitate the movement of droplets at the boundary. Finally, we successfully achieved protein staining experiments on this platform and developed a customized smartphone application for the accurate detection of protein concentration. This innovative closed-open DMF system provides new possibilities for future applications in real-time biological sample processing and detection.
Related Concept Videos
Control Volume and System Representations
The control volume approach considers a stationary region in space through which fluid flows. This region is bounded by a control surface. For instance, in the case of water flowing...
Typical Model Studies
Design Example: Creating a Hydraulic Model of a Dam Spillway