Related Experiment Video
Updated: Aug 18, 2026

Making MR Imaging Child's Play - Pediatric Neuroimaging Protocol, Guidelines and Procedure
Published on: July 30, 2009
Performance and reliability assessment of a lower dose, task-based scoliosis radiography protocol in pediatric
Khalid Al-Dasuqi1,2, Erin Taylor1,3, Lauren Ehrlich1
1Department of Radiology and Biomedical Imaging, Yale School of Medicine, 333 Cedar St, New Haven, CT, 06510, USA.
Background:
Follow-up scoliosis radiographs are performed to assess the degree of spinal curvature and skeletal maturity, which can be done at lower radiation exposures than those in standard-dose radiography.
Objective:
Describe and evaluate a protocol that reduced the radiation in follow-up frontal-view scoliosis radiographs.
Materials And Methods:
We implemented a postero-anterior lower dose modified-technique for scoliosis radiography with task-based definition of adequate image quality and use of technique charts based on target exposure index and patient's height and weight. We subsequently retrospectively evaluated 40 consecutive patients who underwent a follow-up radiograph using the modified-technique after an initial standard-technique radiograph. We evaluated comparisons of proportions for subjective assessment with chi-squared tests, and agreements of reader's scores with intraclass correlation coefficients and Bland-Altman plots. We determined incident air kerma, exposure index, deviation index/standard deviation, dose-area product (DAP), and effective dose for each radiograph. We set statistical significance at P<0.05.
Results:
Forty patients (65% female), aged 4-17 years. Median effective dose was reduced from 39 to 10 µSv (P<0.001), incident air kerma from 139 to 29 µSv (P<0.001), and DAP from 266 to 55 mGy*cm2 (P<0.001). All modified-technique parameters were rated with a mean score of acceptable or above. All modified-technique measurements obtained inter- and intra-observer correlation coefficient agreements of 0.86 ("Good") or greater.
Conclusion:
Substantial dose reduction on follow-up scoliosis imaging with existing radiography units is achievable through task-based definition of adequate image quality and tailoring of radiation to each patient's height and weight, while still allowing for reliable assessment and reproducible measurements.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...