Accuracy of portable ultrasound machines for obstetric biometry
K J Rittenhouse1, B Vwalika1,2, Y Sebastião1
1Department of Obstetrics and Gynecology, University of North Carolina School of Medicine, Chapel Hill, NC, USA.
Objective:
To evaluate the accuracy of two portable ultrasound machines (PUM) in assessing fetal biometry and estimated gestational age (EGA).
Methods:
This was a secondary analysis of data from the Fetal Age Machine Learning Initiative, an observational study of pregnant women in the USA and Zambia. Each participant underwent ultrasound assessment by an experienced sonographer using both a high-specification ultrasound machine (HSUM) and a PUM (Butterfly iQ or Clarius C3) to measure fetal biometry and calculate EGA at each visit. By comparing paired PUM and HSUM scans, we estimated agreement between individual biometry measurements and aggregate gestational age estimates by reporting mean difference, intraclass correlation coefficient (ICC) and Bland-Altman plots, adjusting for trend.
Results:
Between April and December 2021, 818 participants contributed 1386 paired PUM-HSUM ultrasound investigations, of which 991 PUM scans were obtained using the Butterfly iQ device and 395 using the Clarius C3 device. Gestational age at scan ranged from 7 to 38 weeks. Compared with HSUM, the Butterfly iQ PUM had a mean difference of -0.20 (95% CI, -0.60 to 0.20) days in the first trimester and -0.68 (95% CI, -0.93 to -0.44) days in the second/third trimesters. Compared with HSUM, the Clarius C3 PUM had a mean difference of -0.47 (95% CI, -1.11 to 0.18) days in the first trimester and -1.67 (95% CI, -2.10 to -1.25) days in the second/third trimesters. ICCs were 0.989 or greater throughout. Increasing gestational age was associated with increasing error and absolute error in EGA and fetal biometry. Both PUM devices demonstrated a modest trend toward underestimation of EGA with advancing gestational age in second/third-trimester scans, compared with HSUM.
Conclusion:
The Butterfly iQ and Clarius C3 PUM devices were highly accurate in performing fetal biometry in a diverse population from the USA and Zambia. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...