Related Experiment Video
Updated: Jul 9, 2025

Multiplexed Immunofluorescence Analysis and Quantification of Intratumoral PD-1+ Tim-3+ CD8+ T Cells
Published on: February 8, 2018
High Throughput and Noninvasive Exosomal PD-L1 Detection for Accurate Immunotherapy Response Prediction via
Haiyan Wang1, Yanli Liu1, Liyuan Zhang2,3
1College of Pharmaceutical Sciences, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Hebei University, Baoding 071002, China.
Abstract:
Exosomal PD-L1 has been increasingly considered a noninvasive and accurate predictive marker for immunotherapy treatment response. However, the clinical monitoring of exosomal PD-L1 expression is still limited by its complex biological environment as well as the lack of a robust isolation strategy. Here, a Tim4-functionalized magnetic core-shell metal-organic framework (denoted as Fe3O4@SiO2-ILI-01@Tim4) was facilely constructed via layer-by-layer assembly. Owing to the strongly hydrophilic organic ligand of 1,3-bis(4-carboxybutyl)imidazolium bromide (ILI), magnetic Fe3O4@SiO2-ILI-01@Tim4 was endowed with the merits of low nonspecific adsorption and quick, easy, and convenient isolation of exosomes. The capture efficiency of Fe3O4@SiO2-ILI-01@Tim4 reached as high as 90.3 ± 0.5% and the recovery rate for exosomes was up to 93.0 ± 6.1%. The purity of the isolated exosomes was 7.5 times higher than that via the ultracentrifugation (UC) method. By further combination with immunofluorescence assay, high throughput and noninvasive exosomal PD-L1 detection for accurate immunotherapy response prediction was achieved. The prognosis accuracy of the developed Fe3O4@SiO2-ILI-01@Tim4-based strategy reached 85.7%, whereas the prognosis accuracy of the clinical gold standard, the PD-L1 combined positive score (CPS) test, was only 57.1%. Most interestingly, the developed method is especially suitable for those patients receiving false negative results in the CPS test. The proposed Fe3O4@SiO2-ILI-01@Tim4 is a highly efficient and robust technique showing great potential in high throughput and noninvasive exosomal PD-L1 detection for accurately predicting immunotherapy efficacy.
More Related Videos
10:18Author Spotlight: Magnetic Fluorescent Bead-Based Dual-Reporter Flow Analysis of PDL1-Vaxx Peptide Vaccine-Induced Antibody Blockade of the PD-1/PD-L1 Interaction
Published on: July 7, 2023
10:29Semi-automatic PD-L1 Characterization and Enumeration of Circulating Tumor Cells from Non-small Cell Lung Cancer Patients by Immunofluorescence
Published on: August 14, 2019