Related Experiment Video
Updated: Jul 9, 2025

Surgical Model for Single-Staged Tissue-Engineered Urothelial Tubes in Minipigs
Published on: July 5, 2024
Stentless florence robotic intracorporeal neobladder (FloRIN), a feasibility prospective randomized clinical trial
Luca Lambertini1, Fabrizio Di Maida1, Anna Cadenar1
1Department of Experimental and Clinical Medicine, University of Florence, Unit of Oncologic Minimally-Invasive Urology and Andrology, Careggi Hospital, Florence, Italy.
Introduction:
Aim of the study was to evaluate perioperative, postoperative and mid-term functional outcomes of Florence intracorporeal neobladder (FloRIN) configuration technique performed with stentless procedure.
Materials And Methods:
This single institution randomized 1:1 prospective series included consecutive patients treated with Robot-Assisted Radical Cystectomy (RARC) and FloRIN reconfiguration from January 2021 to February 2022. Postoperative complications were graded according to Clavien Dindo classification and divided in early (<30 days from discharge) and delayed (>30 days).
Results:
Overall, 63 patients were included in the analysis. Among these 32 (50.8 %) were treated with RARC + stentless FloRIN while 31 (49.2 %) underwent stent placement procedure. No differences were found in terms of baseline characteristics between the two groups. Stentless procedure was associated with significant shorter console time 328 vs 374 min (p = 0.04) and lower estimated blood loss (EBL) 330 vs 350 ml (p = 0.04) comparing to stent group. As regards perioperative features, no significant differences were recorded in terms of canalization (p = 0.58) and time to drainage removal (p = 0.11) while a shorter length of hospital stay was found in case of stentless procedure (p = 0.04). Early postoperative complications Clavien ≥ 3a occurred in 9.3 % and 12.9 % of patients while delayed major complications were recorded in the 3.1 % and 9.6 % of patients treated with stentless and stent FloRIN, respectively (p = 0.09). As regards the mid-term functional outcomes, no differences were found in terms of kidney function loss in both 3rd and 6th month assessment (p = 0.13 and p = 0.14, respectively).
Conclusions:
In conclusion, Stentless FloRIN is a feasible and safe IntraCorporeal Neobladder technique, as confirmed by the worthy functional and perioperative outcomes achieved in comparison with the standard FloRIN ureteral management strategy.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:19Evaluation of Biomaterials for Bladder Augmentation using Cystometric Analyses in Various Rodent Models
Published on: August 9, 2012