Related Experiment Video
Updated: Jul 9, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
A prospective study on the precision of height data from electronic medical records in tidal volume calculation for
Salman Mohamed1, Kavita Batra2,3, Nicole Pang1
1Kirk Kekorian School of Medicine at University of Nevada, Las Vegas, NV.
Abstract:
Lung-protective ventilation is now the norm for all patients, regardless of the presence of acute respiratory distress syndrome (ARDS), owing to the mortality associated with higher tidal volumes (TV). Clinicians calculate TV using recorded height from medical records and predicted body weight (PBW); however, the accuracy remains uncertain. Our study aimed to validate accurate TV settings for lung-protective ventilation by examining the correlation between the charted height and bedside measurements. In a single-center study, we compared PBW-based TV calculated from recorded height to PBW-based TV from measured height and identified factors causing height overestimation during charting. Our team measured patient height within 24 hours of admission using metal tape. TV calculated from recorded height (6-8 mL/kg PBW) was significantly larger (391.55 ± 65.98 to 522.07 ± 87.97) than measured height-based TV (162.62 ± 12.62 to 470.28 ± 89.64) (P < .01). In the height overestimated group, 57.7% were prescribed TV by healthcare provider, which was more than TV of 8 mL/kg of PBW, as determined by measured height. Negative predictors for height overestimation were male sex (OR: 0.45 [95% CI: 0.25-0.82]; P = .008) and presence of driver's license information (OR: 0.45 [95% CI: 0.25-0.80]; P = .007), whereas Asian ethnicity was a positive predictor (OR: 4.34 [95% CI: 1.09-17.27]; P = .04). The height overestimation group had a higher in-patient mortality rate (38.5%) than the matched/underestimation group (20%) (P < .01). In stadiometer-limited hospitals, the PBW-based TV is overestimated using the recorded height instead of the measured height. In the group where heights were overestimated, over half of the patients received TV prescriptions from healthcare providers that surpassed the TV of calculated 8 mL/kg PBW based on their measured height. The risk factors for height overestimation include female sex, Asian ethnicity, and missing driver's license data. Alternative height measurement methods should be explored to ensure precise ventilation settings and patient safety.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...