Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Curvilinear Motion: Polar Coordinates01:27

Curvilinear Motion: Polar Coordinates

370
In polar coordinates, the motion of a particle follows a curvilinear path. The radial coordinate symbolized as 'r,' extends outward from a fixed origin to the particle, while the angular coordinate, 'θ,' measured in radians, represents the counterclockwise angle between a fixed reference line and the radial line connecting the origin to the particle.
The particle's location is described using a unit vector along the radial direction. Deriving the particle's position...
370
Relative Motion Analysis using Rotating Axes01:25

Relative Motion Analysis using Rotating Axes

469
Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame.
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
469
Curvilinear Motion: Rectangular Components01:23

Curvilinear Motion: Rectangular Components

462
Curvilinear motion characterizes the movement of a particle or object along a curved path, notably evident when envisioning a car navigating a winding road. If the car starts at point A, its position vector is established within a fixed frame of reference, where the ratio of the position vector to its magnitude signifies the unit vector pointing in the position vector's direction.
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
462
Rotation with Constant Angular Acceleration - II01:16

Rotation with Constant Angular Acceleration - II

6.0K
Kinematics is the description of motion. The kinematics of rotational motion discusses the relationships between rotation angle, angular velocity, angular acceleration, and time. One can describe many things with great precision using kinematics, but kinematics does not consider causes. For example, a large angular acceleration describes a very rapid change in angular velocity without any consideration of its cause. Thus, rotational kinematics does not represent the laws of nature.
The first...
6.0K
Angular Momentum about an Arbitrary Axis01:11

Angular Momentum about an Arbitrary Axis

199
Imagine a rigid body with a mass denoted as 'm', which has its center of mass at point G and is rotating around an inertial reference frame. The angular momentum at an arbitrary point P can be calculated by taking the cross product of the position vector and linear momentum vector for each individual mass element.
The velocity of a mass element comprises its translational velocity and the relative velocity instigated by the body's rotation. Substituting the velocity equation into...
199
Relating Angular And Linear Quantities - I01:09

Relating Angular And Linear Quantities - I

6.6K
If the rotational definitions are compared with the definitions of linear kinematic variables from motion along a straight line and motion in two and three dimensions, we can observe a mapping of the linear variables to the rotational ones.
When comparing the linear and rotational variables individually, the linear variable of position has physical units of meters, whereas the angular position variable has dimensionless units of radians, as it is the ratio of two lengths. The linear velocity...
6.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Quantitative lung ultrasound spectroscopy: First comparison with gold standard computed tomography scan and standard lung ultrasound for diagnosis of pneumonia versus cardiogenic pulmonary edema.

The ultrasound journal·2026
Same author

A novel approach to quantify out-of-distribution uncertainty in Neural and Universal Differential Equations.

NPJ systems biology and applications·2026
Same author

Towards reduced ultrasound localization microscopy acquisition times by uncoupling a bi-disperse microbubble population.

The ultrasound journal·2026
Same author

On the interception of the optimal imaging plane for pleural line scanning with automatic robot assisted lung ultrasound: An experimental study.

The ultrasound journal·2026
Same author

Robust parameter estimation and identifiability analysis with hybrid neural ordinary differential equations in computational biology.

NPJ systems biology and applications·2024
Same author

Automatic Segmentation of 2-D Echocardiography Ultrasound Images by Means of Generative Adversarial Network.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2024

Related Experiment Video

Updated: Jul 9, 2025

High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
11:34

High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques

Published on: December 3, 2013

15.7K

A two-dimensional angular interpolation based on radial basis functions for high frame rate ultrafast imaging.

Sajjad Afrakhteh1, Giovanni Iacca1, Libertario Demi1

  • 1Department of Information Engineering and Computer Science, University of Trento, Trento, Italy.

The Journal of the Acoustical Society of America
|November 28, 2023
PubMed
Summary

This study introduces a new method for plane wave imaging (PWI) to improve ultrasound frame rates. By using 2D interpolation, researchers achieved a 3x-4x frame rate boost while maintaining image quality.

More Related Videos

Blood Flow Imaging with Ultrafast Doppler
05:57

Blood Flow Imaging with Ultrafast Doppler

Published on: October 14, 2020

7.7K
Direct Imaging of Laser-driven Ultrafast Molecular Rotation
10:52

Direct Imaging of Laser-driven Ultrafast Molecular Rotation

Published on: February 4, 2017

9.7K

Related Experiment Videos

Last Updated: Jul 9, 2025

High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
11:34

High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques

Published on: December 3, 2013

15.7K
Blood Flow Imaging with Ultrafast Doppler
05:57

Blood Flow Imaging with Ultrafast Doppler

Published on: October 14, 2020

7.7K
Direct Imaging of Laser-driven Ultrafast Molecular Rotation
10:52

Direct Imaging of Laser-driven Ultrafast Molecular Rotation

Published on: February 4, 2017

9.7K

Area of Science:

  • Medical Imaging
  • Ultrasound Technology
  • Signal Processing

Background:

  • Plane Wave Imaging (PWI) is crucial for ultrasound but faces limitations in image quality and frame rate.
  • Coherent Plane Wave Compounding (CPWC) improves image quality by combining PWI data from multiple angles, but requires more data, reducing frame rates.
  • A trade-off exists between image quality and achievable frame rate in CPWC.

Purpose of the Study:

  • To reduce the trade-off between image quality and frame rate in CPWC.
  • To enhance the performance of PWI by optimizing data acquisition and reconstruction.
  • To improve the efficiency of ultrasound imaging for medical applications.

Main Methods:

  • Developed a novel 2D interpolation technique based on radial basis functions.
  • Constructed a 3D spatio-angular data structure to integrate spatial and angular information.
  • Reduced the number of required plane wave transmissions and used interpolation to reconstruct missing angular information.

Main Results:

  • Achieved a 3x to 4x improvement in frame rate.
  • Maintained acceptable image quality compared to traditional CPWC methods.
  • Demonstrated the effectiveness of the technique on medical ultrasound datasets.

Conclusions:

  • The proposed 2D interpolation method significantly enhances frame rates in CPWC.
  • This technique offers a viable solution to balance image quality and speed in plane wave ultrasound imaging.
  • The method shows promise for improving diagnostic capabilities in medical ultrasound.