Related Experiment Video
Updated: Jul 22, 2026

Nondestructive Monitoring of Degradable Scaffold-Based Tissue-Engineered Blood Vessel Development Using Optical Coherence Tomography
Published on: October 3, 2018
Nondestructive volumetric optical analysis of corroded copper oxidation using 1700nm swept-source optical coherence
Abstract:
This study presents a novel nondestructive analysis method for precise characterization of corroded copper oxidation using optical coherence microscopy (OCM). By exploiting the partial light transmission through metallic oxide layers, we employed a specialized OCM system with a wavelength of 1700nm and enhanced the analysis accuracy compared to conventional optical coherence tomography (OCT). The developed OCM system featured a numerical aperture (NA) of 0.15, providing improved surface profiling and higher lateral resolution than OCT. we developed a peak-finding algorithm to accurately determine the thickness of the copper oxide layer from the acquired interference data with zero padding. Our method was validated by comparing the measured thickness profiles with those obtained from scanning electron microscope (SEM) images of corroded metals. The copper oxidation specimens were prepared after heat treatment for 1, 2, 4, and 8 h in an alumina tube furnace at a temperature of 900 °C to find the correlation between the OCM thickness measurement. Additionally, the acquired enface 3D images enabled the identification of local corrosion distribution within a 4 mm × 4 mm area. The en-face mapping images are utilized to analyze the uniformity of the metal oxidation process across the imaging area of the copper oxidation specimens. With an increase in heat treatment time, the median value of the thickness histogram for the copper oxide within the area consistently remained around 10 µm. However, the thickness variation ranged from -2 µm to 5 µm. This indicates that as the heat treatment time progresses, the thickness of the copper oxide becomes more non-uniform. Our technique holds great potential for nondestructive and noncontact detection of metal corrosion and assessment of corrosion rates in various industrial applications. Future research efforts could focus on expanding the application of OCM to different metals and exploring its commercialization prospects for practical implementation in diverse industries.
More Related Videos
07:24Imaging Corrosion at the Metal-Paint Interface Using Time-of-Flight Secondary Ion Mass Spectrometry
Published on: May 6, 2019
12:18Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys
Published on: June 27, 2022
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Total Internal Reflection Fluorescence Microscopy
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Microbial Corrosion