Related Experiment Video
Updated: Jul 9, 2025

Monitoring Acupuncture Effects on Human Brain by fMRI
Published on: April 8, 2010
Harmonic effects of sham acupuncture at Tsu San Li (St-36) in the radial pulse wave
Kuang-Chieh Hsueh1, Jenq-Haur Wang2, Chi-Ying Chen3
1Department of Family Medicine, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan.
Background And Aim:
Acupuncture has been criticized as a theatrical placebo for the sham effect. Unfortunately, sham tests used in control groups in acupuncture studies have always ignored the underlying biophysical factors, including resonance involved in acupuncture points and meridians.
Experimental Procedure:
In this study, the effects of sham acupuncture at Tsu San Li (St-36) were examined by analyzing noninvasive 30-sec. recordings of the radial arterial pulses for 3 groups of patients treated with different probes (blunt, sharp, and patch) on the superficial skin of the acupuncture point. The 3 groups were then treated with the sharp probe for 3 different periods (16, 30, and 50 s). Then we compared the harmonics of the radial arterial pulse after Fourier transformation before and after the treatment.
Results:
Our results indicated that different probes have effects similar to needle insertion at Tsu San Li. Meanwhile, the harmonic effect of the sharp probe strengthened as time increased.
Conclusions:
This study revealed that the meridian effect of sham testing from mechanical stimulation, even from simple touch, on an acupuncture point, should not be overlooked. Thus, even simple touch can be added to electrical or laser acupuncture.
More Related Videos
07:13Studying the Coding Profiles of Somatic Stimulation on Cardiac-locked Neuronal Responses in the Rat Spinal Dorsal Horn
Published on: May 23, 2025
05:24Author Spotlight: Exploring the Initiation Mechanism of 'Three-Method and Three-Acupoint' Tuina Analgesia in Rats with Nerve Injury
Published on: January 26, 2024
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...