Related Experiment Video
Updated: Jul 9, 2025

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
First-Pass Success of Video Laryngoscope Compared With Direct Laryngoscope in Intubations Performed by Residents in
Akihiko Sugaya1, Keiko Naito1, Tadahiro Goto2
1Emergency and Critical Care Medicine, Tokyo Bay Urayasu Ichikawa Medical Center, Chiba, JPN.
Background:
The video laryngoscope (VL) has been widely used for intubation in the emergency department (ED). However, their effectiveness remains controversial, particularly among airway management performed by residents in the ED.
Methods:
We aimed to examine whether the use of VL, compared to a direct laryngoscope (DL), was associated with higher first-attempt intubation success among intubations performed by residents in the ED. This is a secondary analysis of the data from a prospective, observational, multicentre study of 15 Japanese EDs from April 2012 through March 2020. We included all adult patients who underwent intubation with VL or DL by residents (postgraduate years ≤5) in the ED. The outcome measures were first-pass success and intubation-related adverse events (overall, major, and minor adverse events). To determine the association of VL use with each of the outcomes, we constructed logistic regression models with generalized estimating equations to account for patients clustering within the ED, adjusting for patient demographics, primary indications, intubation difficulty, and intubation methods.
Results:
Of 5,261 eligible patients who underwent an initial intubation attempt by residents, 1,858 (35%) patients were attempted with VL. Intubations performed with VL had a non-significantly higher first-pass success rate than those with DL (77% vs. 64%; unadjusted odds ratio (OR)=1.20; 95% CI=0.87-1.65; P=0.27). This association was significant after adjustment for potential confounders (adjusted OR, 1.33; 95% CI, 1.06-1.67; P=0.01). As for adverse events, the use of VL was associated with a lower rate of any (adjusted OR=0.67; 95% CI=0.51-0.86; P=0.002) and minor (adjusted OR=0.69; 95% CI=0.55-0.87; P=0.002) adverse events.
Conclusion:
The use of VL was associated with a higher first-attempt success rate and a lower rate of any adverse events compared to that with DL among intubations performed by residents in the EDs.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...