Related Experiment Video
Updated: Jul 9, 2025

Investigations on the GaIII Complex of EOB-DTPA and Its 68Ga Radiolabeled Analogue
Published on: August 17, 2016
Exploring Gadolinium-Based Contrast Media for Retrograde Pyelography in the Context of Iodine Allergy
Firaas A Khan1, Joseph Balbona2, David J Hernandez2
1Morsani College of Medicine, University of South Florida, Tampa, USA.
Abstract:
Iodinated contrast media can rarely cause severe allergic reactions during nonvascular urologic imaging procedures. Alternatives like gadolinium-based contrast may help mitigate this risk in susceptible patients. A 66-year-old woman with a documented iodine allergy presented with an obstructing stone in the right ureter. To avoid the risk of an allergic reaction, the decision was made to use an alternative non-iodinated contrast agent for retrograde pyelography prior to ureteral stent placement. Gadobenate dimeglumine, an MRI contrast agent, was diluted 50:50 with saline and utilized successfully to provide adequate opacification for safe stent placement without adverse reaction. The patient underwent repeat pyelography with gadobenate dimeglumine one month later during ureteroscopy without complication. This case demonstrates that diluted gadobenate can serve as an effective alternative to iodinated contrast media in patients at high risk of reaction to iodine-containing agents. While severe reactions to iodinated contrast are uncommon in nonvascular urologic procedures, they can still occur even with premedication. Gadolinium-based agents have been reported to provide sufficient opacification for most urologic interventions, though inferior radiographically to iodinated contrast. Further study on gadolinium efficacy and safety in this setting is warranted. However the present case supports gadobenate dimeglumine as a viable option for retrograde pyelography when allergy risk precludes iodinated contrast use.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...