Swin-YOLOv5: Research and Application of Fire and Smoke Detection Algorithm Based on YOLOv5

Shangjie Ge Zhang1, Fengxi Zhang2, Yuyang Ding3

  • 1College of Science, Northeast Forestry University, Harbin 150040, China.

Related Concept Videos

Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
612
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
251
Trial and Error and Algorithm01:12

Trial and Error and Algorithm

A problem-solving strategy is a plan of action used to find a solution. Different strategies have distinct action plans. Trial and error involves trying different solutions until one works. For instance, to fix a broken printer, you might check ink levels, ensure the paper tray isn't jammed, and verify the printer's connection to your laptop. This method can be time-consuming but is commonly used. Thomas Edison, for example, used trial and error to find a suitable filament for the light...
121
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
6.4K
Classification of Signals01:30

Classification of Signals

In signal processing, signals are classified based on various characteristics: continuous-time versus discrete-time, periodic versus aperiodic, analog versus digital, and causal versus noncausal. Each category highlights distinct properties crucial for understanding and manipulating signals.
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
472
Force Classification01:22

Force Classification

Forces play a crucial role in the study of physics and engineering. They are essential in describing the motion, behavior, and equilibrium of objects in the physical world. Forces can be classified based on their origin, type, and direction of action.
Contact and non-contact forces are two of the most widely used categories of forces. As the name suggests, contact forces require physical contact between two objects to act upon each other. Examples of contact forces include frictional,...
1.2K