Effectiveness of Face mask only oxygenation and apnoeic oxygenation in addition to face mask in sustaining PaO2
R Preya1, M Ravishankar1, R Sripriya1
1Department of Anaesthesiology, Mahatma Gandhi Medical College and Research Institute, Sri Balaji Vidyapeeth University, Pillaiyarkuppam, Puducherry, India.
Background And Aims:
Apnoeic oxygenation, although useful during elective intubations, has not shown consistent beneficial results during emergency intubations in critically ill patients. We aimed to study the effectiveness of adding apnoeic oxygenation to our routine practice of using facemask alone, in emergency laparotomy patients needing rapid sequence induction (RSI), for sustaining partial pressure of oxygen (PaO2).
Material And Methods:
Seventy-two patients undergoing RSI for emergency laparotomy were randomly allocated to either receive pre-oxygenation with 5 L/min of oxygen (O2) with a facemask (Group-FM) or apnoeic oxygenation with 10 L/min of O2 through a nasal catheter in addition to pre-oxygenation (Group-NC). Apnoea (90 s) was allowed from the removal of the facemask before the resumption of ventilation. Arterial blood gas analysis was done at the baseline, following pre-oxygenation and after 90 s of apnoea to study the PaO2 and partial pressure of carbon dioxide (PaCO). The circuit O2 concentrations (fraction of inspired [FiO2] and end-tidal [EtO2]) were also noted to ensure a steady state of O2 uptake was reached.
Results:
The circuit O2 concentrations were 90 ± 4% in group FM and 93 ± 5% in Group-NC. The FiO2-EtO2 difference was 4% in both groups. During the 90 s apnoea following pre-oxygenation, there was a fall in the PaO2 by 38% in Group-FM and 12% in Group-NC (P = 0.000). Increase in PaCO2 was similar in both groups (Group-FM: 44 [range: 32-55] mmHg; Group-NC: 42 [range: 33-54] mmHg, P = 0.809).
Conclusion:
Apnoeic insufflation of O2 using a nasopharyngeal catheter along with facemask oxygenation is more effective in sustaining PaO2 for 90 s during RSI than facemask-only oxygenation in patients undergoing emergency laparotomy.
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...