Related Experiment Video
Updated: Jul 9, 2025

Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Encouraging Regular Aortic Valve Opening for EVAHEART 2 LVAD Support Using Virtual Patient Hemodynamic Speed
Jasmine Martinez1, Kelsey Smegner2, Masae Tomoda2
1From the Department of Biomedical Engineering and Science, Florida Institute of Technology, Melbourne, Florida.
None:
This study focuses on investigating the EVAHEART 2 left ventricular assist device (LVAD) toward designing optimal pump speed modulation (PSM) algorithms for encouraging aortic valve (AV) flow. A custom-designed virtual patient hemodynamic model incorporating the EVAHEART 2 pressure-flow curves, cardiac chambers, and the systemic and pulmonary circulations was developed and used in this study. Several PSM waveforms were tested to evaluate their influence on the mean arterial pressure (MAP), cardiac output (CO), and AV flow for representative heart failure patients. Baseline speeds were varied from 1,600 to 2,000 rpm. For each baseline speed, the following parameters were analyzed: 1) PSM ratio (reduced speed/baseline speed), 2) PSM duration (3-7 seconds), 3) native ventricle contractility, and 4) patient MAP of 70 and 80 mm Hg. More than 2,000 rpm virtual patient scenarios were explored. A lower baseline speed (1,600 and 1,700 rpm) produced more opportunities for AV opening and more AV flow. Higher baseline speeds (1,800 and 2,000 rpm) had lower or nonexistent AV flow. When analyzing PSM ratios, a larger reduction in speed (25%) over a longer PSM (5+ seconds) duration produced the most AV flow. Lower patient MAP and increased native ventricle contractility also contributed to improving AV opening frequency and flow. This study of the EVAHEART 2 LVAD is the first to focus on leveraging PSM to enhance pulsatility and encourage AV flow. Increased AV opening frequency can benefit aortic root hemodynamics, thereby improving patient outcomes.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...