Development of hard x-ray photoelectron spectroscopy using synchrotron radiation x-ray up to 30 keV
Satoshi Yasuno1, Okkyun Seo1, Yasumasa Takagi1
1Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan.
Abstract:
Hard X-ray photoelectron spectroscopy (HAXPES) is a powerful tool for investigating the chemical and electronic states of bulk and buried interfaces non-destructively due to its large probing depth. To obtain a much larger probing depth and measure deeper regions than conventional HAXPES, we have developed a high-energy HAXPES (HE-HAXPES) system excited by photon energies up to 30 keV. This system is achieved by combining an applied bias voltage on the sample with a conventional hemispherical electron energy analyzer. By utilizing this system, we successfully observed a Si 1s peak from the bulk-Si substrate underneath the 110-nm-thick SiO2 film at a photon energy of 30 keV. Moreover, the system found that the asymmetrical spectral shape of the Si substrate signal originated from the electronic state, which is upward band bending formed at the interface between the SiO2 film and Si substrate. The HE-HAXPES system, excited by photon energy up to 30 keV, could be a very useful tool to yield genuine insights into the chemical and electronic states in deeply buried regions.
More Related Videos
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....