Related Experiment Video
Updated: Jul 9, 2025

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Single time point quantitation of cerebral glucose metabolism by FDG-PET without arterial sampling
Paul Cumming1,2, André H Dias3, Lars C Gormsen3,4
1Department of Nuclear Medicine, Bern University Hospital, Freiburgstrasse 18, INO B 214.C, 3010, Bern, Switzerland. paul.k.cumming@gmail.com.
Background:
Until recently, quantitation of the net influx of 2-[18F]fluorodeoxyglucose (FDG) to brain (Ki) and the cerebrometabolic rate for glucose (CMRglc) required serial arterial blood sampling in conjunction with dynamic positron emission tomography (PET) recordings. Recent technical innovations enable the identification of an image-derived input function (IDIF) from vascular structures, but are frequently still encumbered by the need for interrupted sequences or prolonged recordings that are seldom available outside of a research setting. In this study, we tested simplified methods for quantitation of FDG-Ki by linear graphic analysis relative to the descending aorta IDIF in oncology patients examined using a Biograph Vision 600 PET/CT with continuous bed motion (Aarhus) or using a recently installed Biograph Vision Quadra long-axial field-of-view (FOV) scanner (Bern).
Results:
Correlation analysis of the coefficients of a tri-exponential decomposition of the IDIFs measured during 67 min revealed strong relationships among the total area under the curve (AUC), the terminal normalized arterial integral (theta(52-67 min)), and the terminal image-derived arterial FDG concentration (Ca(52-67 min)). These relationships enabled estimation of the missing AUC from late recordings of the IDIF, from which we then calculated FDG-Ki in brain by two-point linear graphic analysis using a population mean ordinate intercept and the single late frame. Furthermore, certain aspects of the IDIF data from Aarhus showed a marked age-dependence, which was not hitherto reported for the case of FDG pharmacokinetics.
Conclusions:
The observed interrelationships between pharmacokinetic parameters in the IDIF measured during the PET recording support quantitation of FDG-Ki in brain using a single averaged frame from the interval 52-67 min post-injection, with minimal error relative to calculation from the complete dynamic sequences.
More Related Videos
07:28Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025
09:07Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET