Related Experiment Video
Updated: Jul 9, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Deep learning-based attenuation correction method in 99mTc-GSA SPECT/CT hepatic imaging: a phantom study
Masahiro Miyai1,2, Ryohei Fukui3, Masahiro Nakashima4
1Department of Radiological Technology, Graduate School of Health Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama-Shi, Okayama, 700-8558, Japan. miya0210@hp.kawasaki-m.ac.jp.
Abstract:
This study aimed to evaluate a deep learning-based attenuation correction (AC) method to generate pseudo-computed tomography (CT) images from non-AC single-photon emission computed tomography images (SPECTNC) for AC in 99mTc-galactosyl human albumin diethylenetriamine pentaacetic acid (GSA) scintigraphy and to reduce patient dosage. A cycle-consistent generative network (CycleGAN) model was used to generate pseudo-CT images. The training datasets comprised approximately 850 liver phantom images obtained from SPECTNC and real CT images. The training datasets were then input to CycleGAN, and pseudo-CT images were output. SPECT images with real-time CT attenuation correction (SPECTCTAC) and pseudo-CT attenuation correction (SPECTGAN) were acquired. The difference in liver volume between real CT and pseudo-CT images was evaluated. Total counts and uniformity were then used to evaluate the effects of AC. Additionally, the similarity coefficients of SPECTCTAC and SPECTGAN were assessed using a structural similarity (SSIM) index. The pseudo-CT images produced a lower liver volume than the real CT images. SPECTCTAC exhibited a higher total count than SPECTNC and SPECTGAN, which were approximately 60% and 7% lower, respectively. The uniformities of SPECTCTAC and SPECTGAN were better than those of SPECTNC. The mean SSIM value for SPECTCTAC and SPECTGAN was 0.97. We proposed a deep learning-based AC approach to generate pseudo-CT images from SPECTNC images in 99mTc-GSA scintigraphy. SPECTGAN with AC using pseudo-CT images was similar to SPECTCTAC, demonstrating the possibility of SPECT/CT examination with reduced exposure to radiation.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020