[Relationship between cardiac output, heart rate and microcirculation in patients with multiorgan dysfunction
Wiebke Supthut1, Sebastian Nuding2, Andreas Wienke3
1Klinik für Innere Medizin III, Universitätsklinikum Halle (Saale), Martin-Luther-Universität Halle-Wittenberg, Ernst-Grube-Straße 40, 06120, Halle (Saale), Deutschland. Wiebke.Supthut@t-online.de.
Background:
Multiple organ dysfunction syndrome (MODS) is one of the main causes of death in intensive care units. There is evidence that microcirculation in sepsis and coronary shock is regulated separately from hemodynamics. This study investigates the relationship between heart rate (HR), cardiac output (CO) and microcirculation in patients with MODS.
Methods:
This is a partial analysis of the "MODIFY study" (Reducing Elevated Heart Rate in Patients With Multiple Organ Dysfunction Syndrome [MODS] by Ivabradine). During the period 05/2010-09/2011, the microcirculation of 46 patients with septic and coronary MODS was measured using the sidestream dark field technique on the day of inclusion and 96 h later. Patients were randomized into a control and ivabradine treatment group.
Results:
Overall, there is a relevant improvement in microcirculation over time small perfused vessels, SPV [%] on day 0, d0:56.5 ± 34.2/d4:73.2 ± 22.1 (p = 0.03); perfused vessel density, PVDsmall [1/mm2] d0:7.5 ± 5.0/d4:9.8 ± 3.4 (p = 0.04); proportion of perfused vessels, PPVsmall [%] d0:51.6 ± 31.6/d4:66.7 ± 21.8 (p = 0.04); microcirculatory flow index, MFI d0:1.7 ± 1.0/d4:2.2 ± 0.7 (p = 0.05). Administration of ivabradine shows no effect. In patients with coronary MODS, there is a relevant correlation between microcirculatory parameters and cardiac output (SPV [%]: r = 0.98, p = 0.004). Patients with coronary MODS show better microcirculation values at high heart rates (> 100 bpm), while patients with septic MODS show an opposite relationship.
Conclusion:
The results indicate that in critically ill patients, depending on the genesis of the MODS, there are different relationships between HF or CO values, on the one hand, and the parameters of the microcirculation, on the other.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
12:37Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Pathophysiology of Cardiac Performance
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Pathophysiology of Heart Failure