Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Dummy molecularly imprinted polymer-based solid-phase extraction method for the determination of some phthalate
Melike Küçük1, Bilgen Osman1, Elif Tümay Özer1
1Department of Chemistry, Faculty of Arts and Science, Bursa Uludag University, Görükle, Bursa 16059, Turkey.
Abstract:
A dummy molecularly imprinted polymer-based solid-phase extraction (SPE) sorbent was used for the selective extraction of some phthalate monoesters, monoethyl phthalate (MEP), monobutyl phthalate (MnBP) and mono-(2-ethylhexyl) phthalate (MEHP) in urine prior to gas-chromatography-mass spectrometry (GC-MS) analysis. Diethyl phthalate (DEP), a phthalate ester, was successfully used as a dummy template to prepare selective sorbent for MEP, MnBP, and MEHP extraction. DEP-imprinted poly(ethylene glycol dimethacrylate N-methacryloyl-l-tryptophan methyl ester) (DPEMT) microbeads were synthesized by suspension polymerization and characterized by Fourier Transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and Brunauer Emmet Teller (BET) analysis. The critical parameters (i.e., pH, sorbent amount, ionic strength, sample volume, elution solvent) affecting the extraction performance of the DPEMT-SPE sorbent were optimized. Under optimum conditions, good linearities were obtained in the concentration range of 4 to 60 ng/mL with determination coefficients (R2) of greater than 0.9959. The developed SPE method provided low limits of detection (LOD) of 0.05-1.20 ng/mL and limits of quantification (LOQ) of 0.18-4.01 ng/mL with relative standard deviations (RSDs) of less than 8.95 % for intra- and inter-day analyses. The proposed SPE method was used to analyze phthalate monoesters in spiked urine samples, and recoveries of 97.45-109.26 % were obtained. DPEMT-SPE sorbent was reused for 15 times without any losses of performance. Consequently, a highly selective and sensitive SPE method based on a dummy molecularly imprinted polymer combined with GC-MS was successfully developed to monitor human phthalate exposure via urine samples.
More Related Videos
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...