Related Experiment Video
Updated: Jul 29, 2026

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Simple dual-readout immunosensor based on phosphate-triggered and potassium permanganate for visual detection of
Zi-Jian Chen1, Ai-Jun Huang1, Lin Luo2
1School of Food & Pharmaceutical Engineering, Zhaoqing University, Zhaoqing, 526061, People's Republic of China; Laboratory of Quality & Safety Risk Assessment for Agro-products (Zhaoqing), Ministry of Agriculture and Rural Affairs, Zhaoqing, 526061, People's Republic of China; Guangdong Engineering Technology Research Center of Food & Agricultural Product Safety Analysis and Testing, Zhaoqing, 526061, People's Republic of China.
Abstract:
Multicolor-based visual immunosensor is a promising tool for rapid analysis without the use of bulky instruments. Herein, an anti-fenitrothion nanobody-alkaline phosphatase fusion protein (VHHjd8-ALP) was employed to develop a multicolor visual immunosensor (MVIS) and a ratiometric fluorescence MVIS (RFMVIS, respectively). After one-step competitive immunoassay, the VHHjd8-ALP bound to microplate catalyzed phenyl phosphate disodium salt (ArP) into phenol. Under high alkaline condition (pH 12), the phenol reduced KMnO4 to intermediate (K2MnO4) and further to MnO2 in alkaline condition (pH 12), accompanied by a visible color transition of purple-green-yellow, which can be used for semiquantitative visual analysis or qualitative detection by measuring RGB value. RFMVIS was proposed on the basis of MVIS to further improve sensitivity. The CdTe quantum dot and fluorescein were used as signal probes to develop the fluorescent immunosensor. The CdTe dots with red emission (644 nm) was quenched by oxidation of KMnO4, whereas the fluorescein with green emission (520 nm) remained constant, accompanied by a fluorescent color transition of green-yellow-red. By measuring the ratio of the fluorescence intensity (I644/I520), the ratiometric fluorescence immunosensor was developed for qualitative analysis. The two visual immunosensors were sensitive and simple, and they showed good accuracy and practicability in the recovery test, thus are ideal tools for rapid screening.
More Related Videos
10:59Use of Label-free Optical Biosensors to Detect Modulation of Potassium Channels by G-protein Coupled Receptors
Published on: February 10, 2014
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017