The Association of Incidental Radiation Dose to the Heart Base with Overall Survival and Cardiac Events after
G M Walls1, J O'Connor2, M Harbinson3
1Cancer Centre Belfast City Hospital, Belfast Health & Social Care Trust, Belfast, UK; Patrick G Johnston Centre for Cancer Research, Queen's University Belfast, Belfast, UK.
Aims:
Cardiac disease is a dose-limiting toxicity in non-small cell lung cancer radiotherapy. The dose to the heart base has been associated with poor survival in multiple institutional and clinical trial datasets using unsupervised, voxel-based analysis. Validation has not been undertaken in a cohort with individual patient delineations of the cardiac base or for the endpoint of cardiac events. The purpose of this study was to assess the association of heart base radiation dose with overall survival and the risk of cardiac events with individual heart base contours.
Materials And Methods:
Patients treated between 2015 and 2020 were reviewed for baseline patient, tumour and cardiac details and both cancer and cardiac outcomes as part of the NI-HEART study. Three cardiologists verified cardiac events including atrial fibrillation, heart failure and acute coronary syndrome. Cardiac substructure delineations were completed using a validated deep learning-based autosegmentation tool and a composite cardiac base structure was generated. Cox and Fine-Gray regressions were undertaken for the risk of death and cardiac events.
Results:
Of 478 eligible patients, most received 55 Gy/20 fractions (96%) without chemotherapy (58%), planned with intensity-modulated radiotherapy (71%). Pre-existing cardiovascular morbidity was common (78% two or more risk factors, 46% one or more established disease). The median follow-up was 21.1 months. Dichotomised at the median, a higher heart base Dmax was associated with poorer survival on Kaplan-Meier analysis (20.2 months versus 28.3 months; hazard ratio 1.40, 95% confidence interval 1.14-1.75, P = 0.0017) and statistical significance was retained in multivariate analyses. Furthermore, heart base Dmax was associated with pooled cardiac events in a multivariate analysis (hazard ratio 1.75, 95% confidence interval 1.03-2.97, P = 0.04).
Conclusions:
Heart base Dmax was associated with the rate of death and cardiac events after adjusting for patient, tumour and cardiovascular factors in the NI-HEART study. This validates the findings from previous unsupervised analytical approaches. The heart base could be considered as a potential sub-organ at risk towards reducing radiation cardiotoxicity.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
04:04Endobronchial Ultrasound-guided Intratumoral Injection of Cisplatin for the Treatment of Isolated Mediastinal Recurrence of Lung Cancer
Published on: February 12, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Biological Effects of Radiation