Related Experiment Video
Updated: Jul 9, 2025

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Prognostic value of capillary refill time in adult patients: a systematic review with meta-analysis
Matthias Jacquet-Lagrèze1,2,3, Aymeric Pernollet4,5, Eduardo Kattan6,7
1Service d'anesthésie-Réanimation, Hôpital Cardiologique Louis Pradel, 59 Bd Pinel, 69500, Hospices Civils de LyonBron, France. matthias.jacquet-lagreze@chu-lyon.fr.
Purpose:
Acute circulatory failure leads to tissue hypoperfusion. Capillary refill time (CRT) has been widely studied, but its predictive value remains debated. We conducted a meta-analysis to assess the ability of CRT to predict death or adverse events in a context at risk or confirmed acute circulatory failure in adults.
Method:
MEDLINE, EMBASE, and Google scholar databases were screened for relevant studies. The pooled area under the ROC curve (AUC ROC), sensitivity, specificity, threshold, and diagnostic odds ratio using a random-effects model were determined. The primary analysis was the ability of abnormal CRT to predict death in patients with acute circulatory failure. Secondary analysis included the ability of CRT to predict death or adverse events in patients at risk or with confirmed acute circulatory failure, the comparison with lactate, and the identification of explanatory factors associated with better accuracy.
Results:
A total of 60,656 patients in 23 studies were included. Concerning the primary analysis, the pooled AUC ROC of 13 studies was 0.66 (95%CI [0.59; 0.76]), and pooled sensitivity was 54% (95%CI [43; 64]). The pooled specificity was 72% (95%CI [55; 84]). The pooled diagnostic odds ratio was 3.4 (95%CI [1.4; 8.3]). Concerning the secondary analysis, the pooled AUC ROC of 23 studies was 0.69 (95%CI [0.65; 0.74]). The prognostic value of CRT compared to lactate was not significantly different. High-quality CRT was associated with a greater accuracy.
Conclusion:
CRT poorly predicted death and adverse events in patients at risk or established acute circulatory failure. Its accuracy is greater when high-quality CRT measurement is performed.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring pulse