Related Experiment Video
Updated: Jul 9, 2025

Ultrasonic-Assisted Extraction of Cannabidiolic Acid from Cannabis Biomass
Published on: May 27, 2022
Factors influencing the in situ formation of Δ9-THC from cannabidiol during GC-MS analysis
Ya-Chih Cheng1, Sarah Kerrigan1
1Department of Forensic Science, Sam Houston State University, Huntsville, Texas, USA.
Abstract:
Gas chromatography-mass spectrometry (GC-MS) is widely used for the identification of cannabinoids in seized plant material. Conditions used for instrumental analysis should maximize decarboxylation, while minimizing the in situ production of Δ9-THC inside the GC inlet. In this study, decarboxylation of the acidic Δ9-THC precursor and in situ degradation of cannabidiol (CBD) were investigated using seven commercial GC liners with different deactivation chemistries and geometries. While the inlet temperature was previously optimized at 250°C in a previously validated assay, we systematically examined the temperature-dependent decarboxylation of tetrahydrocannabinolic acid-A (Δ9-THCA-A) and cyclization of CBD between 230°C and 310°C using different liners using favorable and unfavorable conditions. Significant differences in decarboxylation rate and CBD cyclization were observed between different liner types. While no temperature-dependent differences in decarboxylation rate were observed within liner type, liner-dependent differences were observed (α = 0.05), particularly between those with different geometry. In contrast, temperature and liner-dependent differences were observed for in situ formation of Δ9-THC (α = 0.05). This was influenced by liner geometry and to a smaller extent by surface deactivation. Effects were exacerbated with liner usage. While significant differences were observed using new and used GC liners, differences between liners of the same type but different lot numbers were not observed. Inter-instrument differences using the same liner were also evaluated and had minimal effect. Liner- and temperature-dependent effects were also confirmed using more than 20 cannabis plant extracts. Careful selection of liner, inlet conditions, and regular preventive maintenance can mitigate the risks associated with in situ formation Δ9-THC from CBD.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...