Multidimensional Ultrasound Evaluation of Diastasis Recti Abdominis During Different Gestational Periods
Xiao-Han Guo1, Hua Wang1, Sheng-Jiang Chen2
1Department of Ultrasonic, Luoyang Central Hospital Affiliated to Zhengzhou University, Luoyang, China.
Objective:
The purpose of this study is to explore the application value of two-dimensional ultrasound and shear wave elastography (SWE) in the multidimensional evaluation of diastasis recti abdominis (DRA) during different gestational periods.
Methods:
A cohort of 202 gravidas that were examined in our hospital between June 2021 and September 2022 were selected for the purpose of the study, which included 26 cases with <14 weeks of pregnancy, 36 cases in the 14th-27th week of pregnancy, 36 cases in the 28th-34th week of pregnancy, 32 cases in the 35th-38th week of pregnancy, 45 cases at 42 days postpartum, and 27 cases at 3 months postpartum. The inter-rectus distance (IRD) and the thickness in each gestational period were measured, and Young's modulus of the rectus abdominis at different gestational periods was measured using SWE by two sonographers. The differences in IRD, thickness, and elasticity characteristics during different periods, and the correlation between rectus abdominis elasticity and IRD, thickness, body mass index (BMI), neonatal weight, and delivery mode were analyzed and compared. The consistency of SWE parameters obtained by different sonographers was also compared.
Results:
There were significant differences in IRD, thickness, and Young's modulus during different gestational periods (P = .000, P < .001, P < .001). Early postpartum IRD and Young's modulus did not restore to the level of early pregnancy (P < .001, P < .001), while the thickness of rectus abdominis was not significantly different from that of early pregnancy (P = .211). The Young's modulus of rectus abdominis was negatively correlated with the IRD (r = .515), positively correlated with the thickness of rectus abdominis (r = .408), and weakly negatively correlated with maternal BMI (r = -.296). There was no significant correlation with neonatal weight or delivery mode (P = .147, .648). The Bland-Altman plot showed that the two sonographers had good consistency in evaluating the elasticity of rectus abdominis by SWE.
Conclusion:
The multidimensional evaluation of DRA by ultrasound is feasible and IRD and Young's modulus can be used to evaluate the postpartum recovery of DRA. The combination of the two can objectively reflect the severity of DRA morphology and function.
More Related Videos
05:51Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
07:41Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Related Concept Videos
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessment of the Abdomen III: Palpation