Related Experiment Video
Updated: Jul 9, 2025

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
The Center-Center Image Closely Approximates Other Methods for Syndesmosis Reduction Clamp Placement
Nicholas J Jackson1,2, Koen Flores1, Andrew Blake3
1J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida.
Abstract:
BackgroundThe optimal placement for a syndesmosis reduction clamp remains an open question. This study compared the center-center axis, which localizes clamp placement using only an internally rotated lateral ankle X-ray, with other common approaches, whose accuracy can only be confirmed using computed tomography (CT).MethodsBone models of anatomically aligned (n = 6) and malreduced (n = 48) limbs were generated from CT scans of cadaveric specimens. Four axes for guiding clamp placement (center-center, centroid, B2, and trans-syndesmotic) were then analyzed, using digitally reconstructed radiographs derived from the bone models. Each axis' location was defined using angle-height pairs that describe axis orientation along the full anatomical region where syndesmosis fixation occurs.ResultsIn anatomically aligned limbs, the center-center axis was located on average (±95% CI [confidence interval]), 0.64° (±0.50°) internal rotation, 1.03° (±0.73°) internal rotation, and 2.09° (±7.29°) external rotation from the centroid, B2, and trans-syndesmotic axes, respectively. Fibular displacement altered the magnitude of limb rotation needed to identify the center-center axis.ConclusionThe center-center technique is a valid method that closely approximates previously described methods for syndesmosis clamp placement without using CT, and the magnitude of C-arm rotation needed to transition from a talar dome lateral to a center-center view may be a potential method for assessing syndesmosis reduction.Levels of Evidence:Level III: Retrospective comparative study.
More Related Videos
Related Concept Videos
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Method of Joints: Problem Solving II
Method of Joints: Problem Solving I
Method of Joints
Since plane truss members are in the same plane, each joint is subjected to a coplanar and concurrent force system. To apply the method of joints, the first step is to...