Diurnal cardio-respiratory changes in ambulatory individuals deciphered using a multi-parameter wearable device
Dean Nachman1,2, Arik Eisenkraft2,3, Yotam Kolben1
1Heart Institute, Hadassah Medical Center, The Hebrew University of Jerusalem, Jerusalem, Israel.
Background:
Recent technological developments enable big data-driven insights on diurnal changes. This study aimed to describe the trajectory of multiple and advanced parameters using a medical-grade wearable remote patient monitor.
Methods:
Parameters were monitored for 24 h in 256 ambulatory participants who kept living their normal life. Parameters included heart rate, blood pressure, stroke volume, cardiac index, systemic vascular resistance, blood oxygen saturation, and respiratory rate. Diurnal variations were evaluated, and analyses were stratified based on sex, age, and body mass index.
Results:
All parameters showed diurnal changes (p < 0.001). Females demonstrated higher heart rate and cardiac index with lower systemic vascular resistance. Obese participants had a higher blood pressure, and lower stroke volume and cardiac index. Systemic vascular resistance was higher among the elderly. Diurnal changes corresponded with awake-sleep hours and differed between sex, age, and body mass index groups.
Conclusion:
Wearable monitoring platforms could decipher hemodynamic changes in subgroups of individuals, and might help with efforts to provide personalized medicine, pre-symptomatic diagnosis and prevention, and drug development.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Volumes and Capacities I
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: