BiGRU-attention for Continuous blood pressure trends estimation through single channel PPG
Ziyi Liu1, Yiming Zhang2, Congcong Zhou3
1Guangdong Transtek Medical Electronics Co., Ltd., Zhongshan, 52843, People's Republic of China.
Background:
Physiological parameter monitoring based on photoplethysmography (PPG) detection has the advantage of fast, portable, and non-invasive. Changes in the morphology of the PPG waveform can reflect the effect of arterial elasticity changes on blood pressure (BP). However, machine learning models and non-recurrent neural network models typically ignore the time-dependency of continuous PPG data, leading to the decrease of accuracy or the increased calibration frequency.
Objective:
This paper proposes a BiGRU model with attention to estimate BP trends, which uses a single-channel PPG signal combined with demographic information to estimate continuous BP trends point-by-point and to discuss the impact of calibration cycle.
Methods:
This paper selects 15 typical subjects from two groups with/without cardiovascular disease (CVD) and evaluates the model performance. Regarding the calibration frequency problem, we set two modes of non-calibration and calibration to validate the results of blood pressure trends estimation.
Results:
In the calibration mode, the estimation errors (ME ± STD) of SBP for CVD/non-CVD groups are 0.91 ± 10.58 mmHg/0.17 ± 10.06 mmHg respectively, and DBP are 0.34 ± 5.28 mmHg/-0.19 ± 5.36 mmHg; in the non-calibration mode, the estimation errors of SBP for CVD/non-CVD groups are 0.27 ± 9.87 mmHg/-0.82 ± 9.92 mmHg respectively, and DBP are -0.63 ± 3.28 mmHg/0.80 ± 4.93 mmHg.
Conclusions:
The results show that the proposed model has high accuracy in estimating BP levels, which is expected to achieve real-time, long-term continuous BP trends monitoring in wearable devices.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...