Related Experiment Video
Updated: Jul 9, 2025

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Deep-learning-based image quality enhancement of CT-like MR imaging in patients with suspected traumatic shoulder
Georg C Feuerriegel1, Kilian Weiss2, Anh Tu Van1
1Department of Radiology, Klinikum Rechts der Isar, School of Medicine, Technical University of Munich, Munich, Germany.
Purpose:
To evaluate the diagnostic performance of CT-like MR images reconstructed with an algorithm combining compressed sense (CS) with deep learning (DL) in patients with suspected osseous shoulder injury compared to conventional CS-reconstructed images.
Methods:
Thirty-two patients (12 women, mean age 46 ± 14.9 years) with suspected traumatic shoulder injury were prospectively enrolled into the study. All patients received MR imaging of the shoulder, including a CT-like 3D T1-weighted gradient-echo (T1 GRE) sequence and in case of suspected fracture a conventional CT. An automated DL-based algorithm, combining CS and DL (CS DL) was used to reconstruct images of the same k-space data as used for CS reconstructions. Two musculoskeletal radiologists assessed the images for osseous pathologies, image quality and visibility of anatomical landmarks using a 5-point Likert scale. Moreover, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated.
Results:
Compared to CT, all acute fractures (n = 23) and osseous pathologies were detected accurately on the CS only and CS DL images with almost perfect agreement between the CS DL and CS only images (κ 0.95 (95 %confidence interval 0.82-1.00). Image quality as well as the visibility of the fracture lines, bone fragments and glenoid borders were overall rated significantly higher for the CS DL reconstructions than the CS only images (CS DL range 3.7-4.9 and CS only range 3.2-3.8, P = 0.01-0.04). Significantly higher SNR and CNR values were observed for the CS DL reconstructions (P = 0.02-0.03).
Conclusion:
Evaluation of traumatic shoulder pathologies is feasible using a DL-based algorithm for reconstruction of high-resolution CT-like MR imaging.
More Related Videos
10:33Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury
Published on: August 14, 2019
08:36Development of an Uncomplicated Mild Traumatic Brain Injury Model Modified by Weight-Drop Method and Evidenced by Magnetic Resonance Imaging
Published on: April 11, 2025
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging