Impact of Interruptions During Screening Mammography on Physician Well-Being and Patient Care
Sora C Yoon1, Nancy Ballantyne2, Lars J Grimm3
1Fellowship Director, Duke Breast Imaging, Department of Radiology, Duke University Medical Center, Durham, North Carolina.
Objective:
To assess the impact of interruptions on radiologists' efficiency, accuracy, and job satisfaction in interpreting screening mammograms.
Methods:
This institutional review board-approved retrospective reader study recruited nine breast radiologists from a single academic institution [name withheld] to interpret 150 screening mammograms performed between December 1, 2008, and December 31, 2015 under two different reading conditions, as follows: (1) uninterrupted batch reading and (2) interrupted reading. The 150 cases consisted of 125 normal mammograms and 25 mammograms with subtle breast cancers. Cases were divided into two groups of 75 cases each (cohort 1 and cohort 2), with a comparable distribution of cancer cases. Four rounds of 75 cases each were conducted with a 6-week washout period between rounds 2 and 3. After completing each interpretation session, readers completed a seven-question survey, assessing perceptions of mental and physical effort, level of frustration, and performance satisfaction. Clinical performance metrics (reading time, recall rate, sensitivity, specificity, accuracy, and positive predictive value 1) were calculated.
Results:
Recall rates were significantly (P = .04) higher during interrupted reading sessions (35.4%) than they were during uninterrupted batch reading sessions (31.4%). Accuracy was significantly (P = .049) worse in the interrupted reading sessions (69.5%), compared with uninterrupted sessions (73.6%). Differences in overall image interpretation times were not statistically significant (P = .065). Compared with uninterrupted batch reading sessions, readers during interrupted sessions reported feeling busier (P < .001), encountered higher levels of cognitive demand (P = .005), experienced elevated levels of physical fatigue (P = .004), and expressed lower levels of satisfaction with their performance (P = .041).
Conclusion:
Interruptions during interpretation of screening mammography have deleterious effects on physician performance and their sense of well-being.
More Related Videos
Related Concept Videos
Barriers to Effective Communication II
Cultural barriers:
Differences in values, beliefs, religion, knowledge, and tradition can significantly impact communication. Awareness of nonverbal cues is critical, especially when conversing with a patient from a different culture. What appears appropriate in one culture may be inappropriate in another.
Semantic barriers:
As a result of their tendency to use...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Methods of Documentation II: POMR